Author
Listed:
- Orakanya Nguansonsakul
(Energy Technology Program, Faculty of Engineering, Prince of Songkla University, Hat Yai 90112, Songkhla, Thailand)
- Juntakan Taweekun
(Department of Mechanical and Mechatronics Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai 90112, Songkhla, Thailand)
- Yanjun Dai
(School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China)
- Tianshu Ge
(School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China)
Abstract
This study investigates the application of dynamic window technologies in condominiums located in hot and humid climates, focusing on Thailand. The research integrates both passive and active window designs aimed at reducing energy consumption by maximizing natural ventilation and daylight, while minimizing heat gain. Dynamic windows, equipped with shading devices, automated controls, and stack-effect ventilation, can achieve significant energy savings by decreasing the need for air conditioning and artificial lighting. The energy performance was assessed through simulations based on Thailand’s Building Energy Code (BEC), resulting in a potential reduction in energy consumption by 3.29 kWh/m 2 annually or approximately 1.6% annually. Moreover, economic analysis showed that applying dynamic windows in condominiums could save up to 506.38 baht per room per year. The lifecycle cost analysis supports their long-term financial viability, achieving payback within 18.4 years and generating further net savings post-payback. The study concludes that dynamic windows are both scalable and sustainable, offering a viable solution for urban developments in tropical regions.
Suggested Citation
Orakanya Nguansonsakul & Juntakan Taweekun & Yanjun Dai & Tianshu Ge, 2024.
"Dynamic Window Technologies for Energy Efficiency in Condominiums in Tropical Climates,"
Sustainability, MDPI, vol. 16(23), pages 1-20, November.
Handle:
RePEc:gam:jsusta:v:16:y:2024:i:23:p:10170-:d:1525915
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:16:y:2024:i:23:p:10170-:d:1525915. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.