IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v15y2023i6p4713-d1089822.html
   My bibliography  Save this article

Pumping-Induced Feed Water Quality Variation and Its Impacts on the Sustainable Operation of a Brackish Water Reverse Osmosis Desalination Plant, City of Hialeah, Florida, USA

Author

Listed:
  • Zoie R. Kassis

    (Department of Biomedical, Environmental and Civil Engineering, U. A. Whitaker College of Engineering, Florida Gulf Coast University, 10501 FGCU Boulevard South, Fort Myers, FL 33965, USA)

  • Weixing Guo

    (Groundwater Teck Inc., 14542 Indigo Lakes Circle, Naples, FL 34119, USA)

  • Robert G. Maliva

    (WSP USA, Inc., 1567 Hayley Lane, Suite 202, Fort Myers, FL 33907, USA)

  • W. Scott Manahan

    (WSP USA, Inc., 1567 Hayley Lane, Suite 202, Fort Myers, FL 33907, USA)

  • Rachel Rotz

    (Department of Marine and Earth Sciences, Florida Gulf Coast University, 10501 FGCU Boulevard South, Fort Myers, FL 33965, USA)

  • Thomas M. Missimer

    (U. A. Whitaker College of Engineering, Florida Gulf Coast University, 10501 FGCU Boulevard South, Fort Myers, FL 33965, USA)

Abstract

Brackish water reverse osmosis (BWRO) desalination of groundwater is believed to be a sustainable method of providing municipal utilities with a high-quality supply in regions where freshwater sources are stressed and not sustainable. A key aspect of water management is the ability to evaluate an aquifer containing brackish water to ascertain future pumping-induced water quality changes and their impacts on the facility operation and economics. The city of Hialeah, Florida, has operated a BWRO facility for the last 9 years. The facility has a maximum design capacity of about 88,000 m 3 /d but is currently operating at about 33,000 m 3 /d. The facility was designed to treat water with a TDS of up to 10,000 mg/L. A detailed hydrogeologic investigation, including groundwater solute-transport modeling, suggested that the salinity of the source water would remain under 10,000 mg/L of TDS during the 30-year life expectancy of the facility. However, after 9 years of operation, it was found that the rate of salinity increase was much higher than predicted (27.5%), at the low rate of 33,000 m 3 /d. If the faculty was operated at the maximum capacity, the ability of the plant to treat the source water might be between 5 and 10 years. The conceptual model used to guide the solute transport modeling was not accurate for this site because it did not incorporate the apparent enhanced leakance through the basal confining unit below the aquifer. The greater leakance was likely caused by undetected, irregularly distributed fracturing of the underlying confining dolostones. The facility will require a major redesign to upgrade the process to be able to treat seawater at a TDS significantly above 10,000 mg/L in the future, should that occur. While the change will be costly, with a high capital cost to change the process, increased energy consumption, and overall higher water treatment cost, it is still more sustainable and has less environmental impact compared to other alternatives (e.g., treating tidal sources of seawater). The use of electricity from nuclear or solar generation could mitigate the environmental impacts of higher power consumption.

Suggested Citation

  • Zoie R. Kassis & Weixing Guo & Robert G. Maliva & W. Scott Manahan & Rachel Rotz & Thomas M. Missimer, 2023. "Pumping-Induced Feed Water Quality Variation and Its Impacts on the Sustainable Operation of a Brackish Water Reverse Osmosis Desalination Plant, City of Hialeah, Florida, USA," Sustainability, MDPI, vol. 15(6), pages 1-18, March.
  • Handle: RePEc:gam:jsusta:v:15:y:2023:i:6:p:4713-:d:1089822
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/15/6/4713/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/15/6/4713/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:15:y:2023:i:6:p:4713-:d:1089822. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.