IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v15y2023i24p16859-d1300437.html
   My bibliography  Save this article

The Feasibility of Rainwater Harvesting Systems in Buildings with Green Roofs: A Case Study Based on the Köppen Climate Classification

Author

Listed:
  • Carla Pimentel-Rodrigues

    (Institute of Information Sciences and Administration (ISCIA), 3810-488 Aveiro, Portugal
    National Association for Quality in Buildings Services (ANQIP), 3810-193 Aveiro, Portugal
    RISCO—Research Center for Risks and Sustainability in Construction, University of Aveiro (Portugal), 3810-193 Aveiro, Portugal)

  • Armando Silva-Afonso

    (National Association for Quality in Buildings Services (ANQIP), 3810-193 Aveiro, Portugal
    RISCO—Research Center for Risks and Sustainability in Construction, University of Aveiro (Portugal), 3810-193 Aveiro, Portugal)

Abstract

The construction of green roofs (GR) combined with rainwater harvesting systems (RWHSs) in buildings can increase the advantages of each of these technologies, being a very promising solution to combat climate change and increase the sustainability of cities. However, the viability of this joint solution significantly depends on local climatic conditions. The planet’s climate classification, known as the Köppen climate classification, is one of the most widely used climate classification systems. The Köppen climate classification divides climates into five main climate groups, with each group being referenced based on seasonal precipitation and temperature patterns. In the specific case of mainland Portugal, according to the Köppen classification, the climate is divided into two regions. In this article, case studies are developed for two Portuguese climatic regions, seeking to demonstrate the possibility of using the Köppen classification as a decision criterion for the eventual inclusion of rainwater harvesting systems in buildings with green roofs. For this study, the results of a previous study were applied, through which we obtained an expression to determine the runoff coefficients of green roofs common in Portugal, concluding that the Köppen climate classification can be used as a prior decision criterion regarding its incorporation or exclusion in rainwater harvesting system buildings combined with green roofs, depending on the location.

Suggested Citation

  • Carla Pimentel-Rodrigues & Armando Silva-Afonso, 2023. "The Feasibility of Rainwater Harvesting Systems in Buildings with Green Roofs: A Case Study Based on the Köppen Climate Classification," Sustainability, MDPI, vol. 15(24), pages 1-12, December.
  • Handle: RePEc:gam:jsusta:v:15:y:2023:i:24:p:16859-:d:1300437
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/15/24/16859/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/15/24/16859/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Flora Silva & Cristina Sousa Coutinho Calheiros & António Albuquerque & Jorge Pedro Lopes & Ana Maria Antão-Geraldes, 2023. "Technical and Financial Feasibility Analysis of Rainwater Harvesting Using Conventional or Green Roofs in an Industrial Building," Sustainability, MDPI, vol. 15(16), pages 1-12, August.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Anna Musz-Pomorska & Marcin K. Widomski & Justyna Gołębiowska, 2024. "Financial Aspects of Sustainable Rainwater Management in Small-Scale Urban Housing Communities," Sustainability, MDPI, vol. 16(2), pages 1-21, January.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:15:y:2023:i:24:p:16859-:d:1300437. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.