Author
Listed:
- Na Zhao
(College of Water Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Yongbo Zhang
(College of Water Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Xuehua Zhao
(College of Water Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Jinrong Niu
(Yangquan Yinying Coal Mine, Yangquan 040500, China)
- Hong Shi
(College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Na Yang
(College of Water Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Tong Gao
(College of Water Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Lina Guo
(College of Ecology, Taiyuan University of Technology, Taiyuan 030024, China)
Abstract
Coal gangue spontaneous combustion is a serious catastrophe associated with mining activities. Generally, the areas of coal gangue spontaneous combustion are regions of tremendous heat accumulation. Mastering the regularity of deep temperature distribution and eliminating internal heat is an effective method to control spontaneous combustion. In this study, using self-developed heat pipe (HP) and intelligent cloud monitoring software, three sets of single pipe experiments were conducted in different temperature areas of the coal gangue dump in Yinying Coal Mine. A fitted model between shallow and deep temperatures was established using the least squares method to perform goodness-of-fit tests and significance analysis, and to analyze the internal temperature variation under the action of an HP. The results show that the quadratic model fits better and the regression is significant, and can be used as an empirical regression formula for the shallow temperature estimation of the deep temperature. The temperature was clearly suppressed by the HP, and the average cooling range reaches 21.44% within 700 h. However, the temperature of the control group without an HP continued to rise by 8%. In the three experimental groups, the effective control radius of the single HP was 3 m. The best cooling was achieved when the gangue depth was 1 to 4 m and the temperature was between 90 °C and 450 °C. The study shows that the HP has a great effect on thermal removal and inhibits spontaneous combustion of the gangue. In addition, this paper also provides a theoretical basis for the technology of HP treatment of spontaneous combustion gangue dumps.
Suggested Citation
Na Zhao & Yongbo Zhang & Xuehua Zhao & Jinrong Niu & Hong Shi & Na Yang & Tong Gao & Lina Guo, 2022.
"Internal Temperature Variation on Spontaneous Combustion of Coal Gangue Dumps under the Action of a Heat Pipe: Case Study on Yinying Coal Mine in China,"
Sustainability, MDPI, vol. 14(16), pages 1-13, August.
Handle:
RePEc:gam:jsusta:v:14:y:2022:i:16:p:9807-:d:883861
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:14:y:2022:i:16:p:9807-:d:883861. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.