Author
Listed:
- Javier Guerrero
(Research, Applied, Technology, Education and Service, Inc., Rio Grande Valley, Edinburg, TX 78540, USA)
- Ahmed Mahmoud
(Department of Civil Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA)
- Taufiqul Alam
(Department of Environmental Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA)
- Muhammed A. Chowdhury
(Department of Environmental Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA)
- Adeniyi Adetayo
(Department of Environmental Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA)
- Andrew Ernest
(Department of Civil Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA)
- Kim D. Jones
(Department of Environmental Engineering, Texas A&M University-Kingsville, Kingsville, TX 78363, USA)
Abstract
Stormwater runoff introduces several pollutants to the receiving water bodies that may cause degradation of the water quality. Stormwater management systems such as detention facilities and wetland can improve the water quality by removing various pollutants associated with the runoff. The objective of this research project is to determine the performance and efficiency of two major regional detention facilities (RDFs) with different designs and structures in reducing pollutants based on various storm events in McAllen, Texas. The two sites are the McAuliffe RDF and the Morris RDF; each site was incorporated with a constructed wetland with a different design and structure to enhance the pollutant removal process. The McAuliffe RDF reduced the concentration and load of many stormwater constituents in comparison to the Morris RDF. The observed concentrations and pollutant loads of suspended solids were much lower in the runoff of the inlet compared to the outlet for both sites. The McAuliffe RDF showed better concentration and load reduction for nutrients, such as nitrogen and phosphorus, of different species. However, both sites did not show a significant improvement of organic material. In addition, the indicator bacteria concentration represented a fluctuation between the inlet and outlet at each site.
Suggested Citation
Javier Guerrero & Ahmed Mahmoud & Taufiqul Alam & Muhammed A. Chowdhury & Adeniyi Adetayo & Andrew Ernest & Kim D. Jones, 2020.
"Water Quality Improvement and Pollutant Removal by Two Regional Detention Facilities with Constructed Wetlands in South Texas,"
Sustainability, MDPI, vol. 12(7), pages 1-21, April.
Handle:
RePEc:gam:jsusta:v:12:y:2020:i:7:p:2844-:d:340844
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:12:y:2020:i:7:p:2844-:d:340844. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.