IDEAS home Printed from https://ideas.repec.org/a/gam/jjopen/v9y2026i1p10-d1889935.html

Melt Damage and Prevention of Gas Nozzle Tip in Close-Coupled Gas Atomization

Author

Listed:
  • Nazuku Kato

    (Fukuda Metal Foil & Powder Co., Ltd., 20 Nakatomi-cho, Nishinoyama, Yamashina-ku, Kyoto 607-8305, Japan)

  • Tetsuji Ohmura

    (Fukuda Metal Foil & Powder Co., Ltd., 20 Nakatomi-cho, Nishinoyama, Yamashina-ku, Kyoto 607-8305, Japan)

  • Takeshi Maruyama

    (Fukuda Metal Foil & Powder Co., Ltd., 20 Nakatomi-cho, Nishinoyama, Yamashina-ku, Kyoto 607-8305, Japan)

  • Yukitaka Hamada

    (Fukuda Metal Foil & Powder Co., Ltd., 20 Nakatomi-cho, Nishinoyama, Yamashina-ku, Kyoto 607-8305, Japan)

  • Toshihiko Shakouchi

    (Graduate School of Engineering, Mie University, Kurimamachiya-cho 1577, Tsu-shi 514-8507, Japan)

Abstract

Gas atomization is one method for producing fine metal powder. In close-coupled gas atomization, a high-speed gas jet is ejected near the molten metal, and the molten metal is further broken down in the shear layer at the outer edge of the jet, producing fine metal powder of several micrometers to several tens of micrometers. By the way, in close-coupled gas atomization, if the protrusion length of the molten metal nozzle is short, a backflow occurs that goes around the melt delivery nozzle tip and reaches the gas nozzle tip, and the small droplets of molten metal that are atomized at the exit of the melt delivery nozzle are carried by this backflow to the gas nozzle tip, causing it to erode. In this study, we experimentally clarified the existence of the backflow for the first time through measurements of velocity distribution, then the flow state of the gas flow inside the gas atomizer was visualized approximately using the atomized water flow, and the existence of a backflow was confirmed. It was shown that microdroplets of water are carried by the backflow and reach the gas nozzle tip. This was also clarified through numerical analysis results for the air flow. Furthermore, the protrusion length of the melt delivery nozzle at which backflow does not occur was determined, and this was verified in actual gas atomization experiments using molten copper. In addition, the length of the melt delivery nozzle at which backflow does not occur, i.e., the gas nozzle tip does not melt, was found. Furthermore, molten-copper experiments were conducted using this gas atomizer to evaluate its performance.

Suggested Citation

  • Nazuku Kato & Tetsuji Ohmura & Takeshi Maruyama & Yukitaka Hamada & Toshihiko Shakouchi, 2026. "Melt Damage and Prevention of Gas Nozzle Tip in Close-Coupled Gas Atomization," J, MDPI, vol. 9(1), pages 1-14, March.
  • Handle: RePEc:gam:jjopen:v:9:y:2026:i:1:p:10-:d:1889935
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2571-8800/9/1/10/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2571-8800/9/1/10/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jjopen:v:9:y:2026:i:1:p:10-:d:1889935. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.