IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v20y2022i1p686-d1020490.html
   My bibliography  Save this article

Bioimpedance-Derived Membrane Capacitance: Clinically Relevant Sources of Variability, Precision, and Reliability

Author

Listed:
  • Valene Garr Barry

    (Department of Obstetrics and Gynecology, Division of Clinical Research, School of Medicine in St. Louis, Washington University, St. Louis, MO 63108, USA)

  • Jasmine L. Chiang

    (Department of Obstetrics and Gynecology, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL 35294, USA)

  • Kaylan G. Bowman

    (Department of Nutrition Sciences, School of Health Professions, The University of Alabama at Birmingham, Birmingham, AL 35294, USA)

  • Kristina D. Johnson

    (Department of Nutrition Sciences, School of Health Professions, The University of Alabama at Birmingham, Birmingham, AL 35294, USA)

  • Barbara A. Gower

    (Department of Nutrition Sciences, School of Health Professions, The University of Alabama at Birmingham, Birmingham, AL 35294, USA)

Abstract

Membrane capacitance (C M ), a bioimpedance-derived measure of cell membrane health, has been suggested as an indicator of health status. However, there are few published data to support its use in clinical settings. Hence, this study evaluated clinically relevant sources of variation, precision, and reliability of C M measurements. This longitudinal study included 60 premenopausal women. Sources of variability (e.g., demographics, body composition, serum measures, diet) were identified by stepwise regression. Precision and reliability were assessed by the coefficient of variation (CV), intraclass correlation coefficients (ICC), and technical error of the measurement (TEM) for intra-day (30 min apart) and inter-day measurements (7–14 days apart). Body composition, temperature, and metabolic activity were identified as sources of variability. C M measurements had high precision (CV = 0.42%) and high reliability for intra-day (ICC = 0.996) and inter-day (ICC = 0.959) measurements, independent of menstrual cycle and obesity status. Our results showed that C M measurements are sensitive to clinical factors and have high precision and reliability. The results of this study suggest that C M is sufficiently reliable for health status monitoring in conditions with variation in body composition, metabolic activity, or body temperature among premenopausal women.

Suggested Citation

  • Valene Garr Barry & Jasmine L. Chiang & Kaylan G. Bowman & Kristina D. Johnson & Barbara A. Gower, 2022. "Bioimpedance-Derived Membrane Capacitance: Clinically Relevant Sources of Variability, Precision, and Reliability," IJERPH, MDPI, vol. 20(1), pages 1-13, December.
  • Handle: RePEc:gam:jijerp:v:20:y:2022:i:1:p:686-:d:1020490
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/20/1/686/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/20/1/686/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:20:y:2022:i:1:p:686-:d:1020490. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.