Author
Listed:
- Masanori Iwasaki
(Tokyo Metropolitan Geriatric Medical Center, 35-2 Sakae-cho, Itabashi-ku, Tokyo 173-0015, Japan)
- Ichinosuke Maeda
(Sumitomo Riko Co., Ltd., 3-1 Higashi, Komaki-shi 485-0041, Japan)
- Yota Kokubo
(Sumitomo Riko Co., Ltd., 3-1 Higashi, Komaki-shi 485-0041, Japan)
- Yoshitomo Tanaka
(Sumitomo Riko Co., Ltd., 3-1 Higashi, Komaki-shi 485-0041, Japan)
- Tetsuji Ueno
(Sumitomo Riko Co., Ltd., 3-1 Higashi, Komaki-shi 485-0041, Japan)
- Wataru Takahashi
(Tokyo Metropolitan Geriatric Medical Center, 35-2 Sakae-cho, Itabashi-ku, Tokyo 173-0015, Japan)
- Yutaka Watanabe
(Tokyo Metropolitan Geriatric Medical Center, 35-2 Sakae-cho, Itabashi-ku, Tokyo 173-0015, Japan
Gerontology, Department of Oral Health Science, Faculty of Dental Medicine, Hokkaido University, Kita 14-Jo Nishi 5-Chome, Kita-ku, Sapporo-shi 060-8586, Japan)
- Hirohiko Hirano
(Tokyo Metropolitan Geriatric Medical Center, 35-2 Sakae-cho, Itabashi-ku, Tokyo 173-0015, Japan)
Abstract
Bite force is an important indicator of masticatory performance. However, existing methods for measuring bite force are either ineffective or expensive. Hence, we developed a novel capacitive-type pressure-mapping sensor that converts mechanical forces into changes in capacitance and calculates bite force. A portable device was fabricated based on this sensor sheet, and the accuracy of the bite-force measurements provided by the device was evaluated. The sensor has a thickness of 1.6 mm and has 63 measurement points. It was inserted into a dental model, where the output value was measured and compared with that of a universal testing machine (AG-IS 100 kN). A regression equation to estimate the bite force was obtained based on the relationship between the output of the capacitive-type pressure-mapping sensor and that of the load cell of the universal testing machine. The estimated bite force from the sensor and the quadratic regression equation closely resembled the known load applied by the compression tester (R 2 = 0.992). We therefore conclude that the developed sensor can measure bite force accurately and effectively. A device with a built-in capacitive-type pressure-mapping sensor can potentially be a user-friendly tool for bite-force measurements in both clinical and epidemiological settings.
Suggested Citation
Masanori Iwasaki & Ichinosuke Maeda & Yota Kokubo & Yoshitomo Tanaka & Tetsuji Ueno & Wataru Takahashi & Yutaka Watanabe & Hirohiko Hirano, 2022.
"Capacitive-Type Pressure-Mapping Sensor for Measuring Bite Force,"
IJERPH, MDPI, vol. 19(3), pages 1-9, January.
Handle:
RePEc:gam:jijerp:v:19:y:2022:i:3:p:1273-:d:731934
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:3:p:1273-:d:731934. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.