IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v19y2022i21p13743-d950491.html
   My bibliography  Save this article

Improvement of Ultrasound Image Quality Using Non-Local Means Noise-Reduction Approach for Precise Quality Control and Accurate Diagnosis of Thyroid Nodules

Author

Listed:
  • Kyuseok Kim

    (Department of Integrative Medicine, Major in Digital Healthcare, Yonsei University College of Medicine, Unju-ro, Gangman-gu, Seoul 06229, Korea
    These authors contributed equally to this work as co-first authors.)

  • Nuri Chon

    (Woori Yonsei Internal Medicine, 370, Anyang-ro, Manan-gu, Anyang-si 13991, Korea
    These authors contributed equally to this work as co-first authors.)

  • Hyun-Woo Jeong

    (Department of Biomedical Engineering, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Korea
    These authors contributed equally to this work as corresponding authors.)

  • Youngjin Lee

    (Department of Radiological Science, College of Health Science, Gachon University, 191, Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Korea
    These authors contributed equally to this work as corresponding authors.)

Abstract

This study aimed to improve the quality of ultrasound images by modeling an algorithm using a non-local means (NLM) noise-reduction approach to achieve precise quality control and accurate diagnosis of thyroid nodules. An ATS-539 multipurpose phantom was used to scan the dynamic range and gray-scale measurement regions, which are most closely related to the noise level. A convex-type 3.5-MHz frequency probe is used for scanning according to ATS regulations. In addition, ultrasound images of human thyroid nodules were obtained using a linear probe. An algorithm based on the NLM noise-reduction approach was modeled based on the intensity and relative distance of adjacent pixels in the image, and conventional filtering methods for image quality improvement were designed as a comparison group. When the NLM algorithm was applied to the image, the contrast-to-noise ratio and coefficient of variation values improved by 28.62% and 19.54 times, respectively, compared with those of the noisy images. In addition, the image improvement efficiency of the NLM algorithm was superior to that of conventional filtering methods. Finally, the applicability of the NLM algorithm to human thyroid images using a high-frequency linear probe was validated. We demonstrated the efficiency of the proposed algorithm in ultrasound images and the possibility of capturing improved images in the dynamic range and gray-scale region for quality control parameters.

Suggested Citation

  • Kyuseok Kim & Nuri Chon & Hyun-Woo Jeong & Youngjin Lee, 2022. "Improvement of Ultrasound Image Quality Using Non-Local Means Noise-Reduction Approach for Precise Quality Control and Accurate Diagnosis of Thyroid Nodules," IJERPH, MDPI, vol. 19(21), pages 1-11, October.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:21:p:13743-:d:950491
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/21/13743/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/21/13743/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:21:p:13743-:d:950491. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.