IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v19y2022i17p10645-d898433.html
   My bibliography  Save this article

A New Culture Method for the Detection of Non-Tuberculous Mycobacteria in Water Samples from Heater–Cooler Units and Extracorporeal Membrane Oxygenation Machines

Author

Listed:
  • Savina Ditommaso

    (Department of Public Health and Pediatrics, University of Turin, 10126 Torino, Italy)

  • Monica Giacomuzzi

    (Department of Public Health and Pediatrics, University of Turin, 10126 Torino, Italy)

  • Gabriele Memoli

    (Department of Public Health and Pediatrics, University of Turin, 10126 Torino, Italy)

  • Jacopo Garlasco

    (Department of Public Health and Pediatrics, University of Turin, 10126 Torino, Italy)

  • Antonio Curtoni

    (Microbiology and Virology Unit, University Hospital Città della Salute e della Scienza di Torino, 10126 Torino, Italy)

  • Marco Iannaccone

    (Microbiology and Virology Unit, University Hospital Città della Salute e della Scienza di Torino, 10126 Torino, Italy)

  • Carla M. Zotti

    (Department of Public Health and Pediatrics, University of Turin, 10126 Torino, Italy)

Abstract

The isolation of non-tuberculous mycobacteria (NTM) from cultures is particularly laborious due to the potential overgrowth of coexisting non-acid fast bacilli. To reduce the overgrowth of these non-mycobacterial organisms, a decontamination step with NaOH or cetylpyridinium chloride is highly recommended before plating the samples on the culture medium. However, due to their toxicity, decontamination solutions tend to decrease NTM recovery from clinical and environmental samples. Here, we tested an alternative method for NTM recovery based on the use of NTM Elite agar, a selective medium that does not require a decontamination step. Using NTM Elite agar, we were able to detect non-tuberculous mycobacteria in 27.7% (30/108) of water samples analyzed. The average time to NTM detection was 18 days, but some strains required longer to grow, perhaps due to the stressful environmental conditions (periodical disinfection of devices). NTM Elite agar’s effectiveness in inhibiting background flora was proven by the isolation of NTM from samples with and without background flora, showing no statistically significant differences in detection rates for different total viable counts of background flora ( p = 0.4989). In conclusion, our findings indicate that effective NTM recovery from HCU- and ECMO-derived water samples can be achieved via filtration and direct culture of the filters on NTM Elite agar. This simple procedure can speed up laboratory work and provide an improved method, successfully resulting in low contamination and high detection rate, in addition to being less time-consuming. Its sensitivity and lack of a decontamination step make this protocol particularly useful for monitoring the effectiveness of device disinfection in hospital settings, even in the presence of low NTM loads. Reading timeframes should probably be extended to 7 weeks (i.e., well beyond the standard 4 weeks advised by the manufacturer), in order to isolate even the slow-growing mycobacteria. However, an extended incubation period is not necessary for exclusion of M. chimaera contamination of the devices, as M. chimaera isolation times do not generally exceed 3 weeks.

Suggested Citation

  • Savina Ditommaso & Monica Giacomuzzi & Gabriele Memoli & Jacopo Garlasco & Antonio Curtoni & Marco Iannaccone & Carla M. Zotti, 2022. "A New Culture Method for the Detection of Non-Tuberculous Mycobacteria in Water Samples from Heater–Cooler Units and Extracorporeal Membrane Oxygenation Machines," IJERPH, MDPI, vol. 19(17), pages 1-11, August.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:17:p:10645-:d:898433
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/17/10645/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/17/10645/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:17:p:10645-:d:898433. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.