One-Year Real-World Study on Comparison among Different Continuous Subcutaneous Insulin Infusion Devices for the Management of Pediatric Patients with Type 1 Diabetes: The Supremacy of Hybrid Closed-Loop Systems

Author

Listed:
  • Bruno Bombaci

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Stefano Passanisi

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Angela Alibrandi

    (Unit of Statistical and Mathematical Sciences, Department of Economics, University of Messina, 98124 Messina, Italy)

  • Giulia D’Arrigo

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Serena Patroniti

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Simona Averna

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Giuseppina Salzano

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

  • Fortunato Lombardo

    (Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Via Consolare Valeria 1, 98124 Messina, Italy)

Abstract

Since their advent in daily clinical practice, continuous subcutaneous insulin infusion (CSII) systems have been increasingly improved, leading to a high percentage of both adult and pediatric patients with diabetes now using insulin pumps. Different types of CSII systems are currently available, which are characterized by different settings and technical features. This longitudinal observational study aims to evaluate real-word glycemic outcomes in children and adolescents with type 1 diabetes using three different CSII devices: hybrid closed-loop (HCL) systems, predictive low glucose (PLGS) systems, and non-automated insulin pumps. The secondary objective was to identify clinical variables that may significantly influence the achievement of therapeutic goals in our study cohort. One-hundred-and-one patients on CSII therapy attending our pediatric diabetes center were enrolled. When compared with the non-automated group, patients using HCL systems showed higher levels of time in target glucose range ( p = 0.003) and lower glucose variability ( p = 0.008). Similarly, we found significantly better glucose metrics in HCL users in comparison to PLGS patients (time in range p = 0.008; coefficient of variation p = 0.009; time above 250 mg/dL p = 0.007). Multiple linear regression models showed that HCL systems (time in range p < 0.001) and high daily percentage of glycemic sensor use (time in range p = 0.031) are predictors for good glycemic control. The introduction and increasing availability of novel technologies for diabetes represent a promising strategy to improve glycemic control and quality of life in pediatric patients with type 1 diabetes. Our real-world data confirm the superiority of HCL systems in terms of improvement of time spent in the target glucose range, prevention of hypoglycemia, and reduction of glycemic variability.

Suggested Citation

  • Bruno Bombaci & Stefano Passanisi & Angela Alibrandi & Giulia D’Arrigo & Serena Patroniti & Simona Averna & Giuseppina Salzano & Fortunato Lombardo, 2022. "One-Year Real-World Study on Comparison among Different Continuous Subcutaneous Insulin Infusion Devices for the Management of Pediatric Patients with Type 1 Diabetes: The Supremacy of Hybrid Closed-L," IJERPH, MDPI, vol. 19(16), pages 1-11, August.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:16:p:10293-:d:891765
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/16/10293/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/16/10293/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:16:p:10293-:d:891765. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.