IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v19y2022i14p8288-d857437.html
   My bibliography  Save this article

Application of High-Performance Liquid Chromatography with Diode Array Detection to Simultaneous Analysis of Reference Antioxidants and 1,1-Diphenyl-2-picrylhydrazyl (DPPH) in Free Radical Scavenging Test

Author

Listed:
  • Małgorzata Tatarczak-Michalewska

    (Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland)

  • Jolanta Flieger

    (Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland)

Abstract

Antioxidant activity can be analyzed by various methods, both in vitro and in vivo. The widely used colorimetric method using the 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging reaction has many limitations, such as interference from photosynthetic pigments naturally found in plant extracts. The DPPH-HPLC eliminates these troubles by enabling the separation of the DPPH free radical (DPPH-R) peak and its reduced form (DPPH-H) from other extract components. However, simultaneous analysis of antioxidants and evaluation of their activity is more complicated. To date, a post-column reaction with DPPH has been used for this purpose. The aim of the current study was the elaboration on a DPPH-RP-HPLC in gradient elution mode for simultaneous evaluation of the antioxidant activity of standards on the basis of DPPH-R peak inhibition, together with the identification of standards, as well as the products of redox reactions. The following antioxidants (AOs) were used as standards: quercetin, resveratrol, Trolox, chlorogenic acid, hesperetin, and coumarin. Flavone was used as the control chemical without antioxidant activity. The separation of the DPPH-R/DPPH-H pair, together with standards and reaction products, was studied on a C18 column using a gradient of acetonitrile from 5 to 60% within 20 min. The stability of DPPH was evaluated with different gradient profiles. The influence of the addition of acetic acid in concentrations of 0.05 to 1%, the duration of the analysis, and the radiation emitted by the UV lamp of a diode array detector on the induction of DPPH decomposition processes were investigated. The most significant parameter affecting DPPH stability appeared to be the acidic environment and water content in the mobile phase. An increase in the water content from 70 to 95% worsened the LOD of DPPH-R from 31.64 nM to 107.31 nM, as measured at 517 nm, and from 189.41 to 1677.05 nM at 330 nm. Each gradient profile provided good linearity (R 2 = 0.9790–0.9977) of the relationship between the DPPH-R as well as DPPH-H peak areas, and a wide concentration range from 0.5 to 2.5 mM for UV-vis detection. Free radical scavenging activity was expressed by the percentage of DPPH-R peak inhibition at 517 nm. This simple method is suitable for monitoring DPPH radical scavenging by AO standards.

Suggested Citation

  • Małgorzata Tatarczak-Michalewska & Jolanta Flieger, 2022. "Application of High-Performance Liquid Chromatography with Diode Array Detection to Simultaneous Analysis of Reference Antioxidants and 1,1-Diphenyl-2-picrylhydrazyl (DPPH) in Free Radical Scavenging ," IJERPH, MDPI, vol. 19(14), pages 1-19, July.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:14:p:8288-:d:857437
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/14/8288/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/14/8288/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:14:p:8288-:d:857437. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.