IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v18y2021i9p4624-d544168.html
   My bibliography  Save this article

Development and Validation of a Sensitive, Specific and Reproducible UPLC-MS/MS Method for the Quantification of OJT007, A Novel Anti-Leishmanial Agent: Application to a Pharmacokinetic Study

Author

Listed:
  • Maria Rincon Nigro

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA)

  • Jing Ma

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA)

  • Ololade Tosin Awosemo

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA
    Department of Clinical Pharmacology Analysis and Reporting, Bristol Myers Squibb, Princeton, NJ 08543, USA)

  • Huan Xie

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA)

  • Omonike Arike Olaleye

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA)

  • Dong Liang

    (Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Texas Southern University, Houston, TX 77004, USA)

Abstract

OJT007 is a methionine aminopeptidase 1 (MetAP1) inhibitor with potent anti-proliferative effects against Leishmania Major . In order to study its pharmacokinetics as a part of the drug development process, a sensitive, specific, and reproducible ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated. Voriconazole was used as the internal standard to generate standard curves ranging from 5 to 1000 ng/mL. The separation was achieved using a UPLC system equipped with an Acquity UPLC BEH C 18 column (2.1 × 50 mm, 1.7 μm) with 0.1% formic acid in acetonitrile and 0.1% formic acid in water as the mobile phase under gradient elution at a flow rate of 0.4 mL/min. The mass analysis was performed with a 4000 QTRAP ® mass spectrometer using multiple-ion reaction monitoring (MRM) in the positive mode, with the transition of m / z 325 → m / z 205 for OJT007 and m / z 350 → m / z 101 for voriconazole. The intra- and inter-day precision and accuracy were within ±15%. The mean extraction recovery and the matrix effect were 95.1% and 7.96%, respectively, suggesting no significant matrix interfering with the quantification of the drug in rat plasma. This study was successfully used for the pharmacokinetic evaluation of OJT007 using the rat as an animal model.

Suggested Citation

  • Maria Rincon Nigro & Jing Ma & Ololade Tosin Awosemo & Huan Xie & Omonike Arike Olaleye & Dong Liang, 2021. "Development and Validation of a Sensitive, Specific and Reproducible UPLC-MS/MS Method for the Quantification of OJT007, A Novel Anti-Leishmanial Agent: Application to a Pharmacokinetic Study," IJERPH, MDPI, vol. 18(9), pages 1-12, April.
  • Handle: RePEc:gam:jijerp:v:18:y:2021:i:9:p:4624-:d:544168
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/18/9/4624/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/18/9/4624/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    OJT007; UPLC-MS/MS; pharmacokinetics; leishmaniasis; rats;
    All these keywords.

    JEL classification:

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:18:y:2021:i:9:p:4624-:d:544168. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.