IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v18y2021i21p11224-d664889.html
   My bibliography  Save this article

A New Paired Associative Stimulation Protocol with High-Frequency Peripheral Component and High-Intensity 20 Hz Repetitive Transcranial Magnetic Stimulation—A Pilot Study

Author

Listed:
  • Sabin Sathyan

    (Research Group of Computational Electromechanics, Department of Electrical Engineering and Automation, Aalto University, 02150 Espoo, Finland
    BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland)

  • Aleksandra Tolmacheva

    (BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland)

  • Sergei Tugin

    (BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland
    Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, 02150 Helsinki, Finland)

  • Jyrki P. Mäkelä

    (BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland)

  • Anastasia Shulga

    (BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland
    Department of Physical and Rehabilitation Medicine, Helsinki University Hospital, 00280 Helsinki, Finland)

  • Pantelis Lioumis

    (BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki and Helsinki University Hospital, 00280 Helsinki, Finland
    Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, 02150 Helsinki, Finland)

Abstract

Paired associative stimulation (PAS) is a stimulation technique combining transcranial magnetic stimulation (TMS) and peripheral nerve stimulation (PNS) that can induce plastic changes in the human motor system. A PAS protocol consisting of a high-intensity single TMS pulse given at 100% of stimulator output (SO) and high-frequency 100-Hz PNS train, or “the high-PAS” was designed to promote corticomotoneuronal synapses. Such PAS, applied as a long-term intervention, has demonstrated therapeutic efficacy in spinal cord injury (SCI) patients. Adding a second TMS pulse, however, rendered this protocol inhibitory. The current study sought for more effective PAS parameters. Here, we added a third TMS pulse, i.e., a 20-Hz rTMS (three pulses at 96% SO) combined with high-frequency PNS (six pulses at 100 Hz). We examined the ability of the proposed stimulation paradigm to induce the potentiation of motor-evoked potentials (MEPs) in five human subjects and described the safety and tolerability of the new protocol in these subjects. In this study, rTMS alone was used as a control. In addition, we compared the efficacy of the new protocol in five subjects with two PAS protocols consisting of PNS trains of six pulses at 100 Hz combined with (a) single 100% SO TMS pulses (high-PAS) and (b) a 20-Hz rTMS at a lower intensity (three pulses at 120% RMT). The MEPs were measured immediately after, and 30 and 60 min after the stimulation. Although at 0 and 30 min there was no significant difference in the induced MEP potentiation between the new PAS protocol and the rTMS control, the MEP potentiation remained significantly higher at 60 min after the new PAS than after rTMS alone. At 60 min, the new protocol was also more effective than the two other PAS protocols. The new protocol caused strong involuntary twitches in three subjects and, therefore, its further characterization is needed before introducing it for clinical research. Additionally, its mechanism plausibly differs from PAS with high-frequency PNS that has been used in SCI patients.

Suggested Citation

  • Sabin Sathyan & Aleksandra Tolmacheva & Sergei Tugin & Jyrki P. Mäkelä & Anastasia Shulga & Pantelis Lioumis, 2021. "A New Paired Associative Stimulation Protocol with High-Frequency Peripheral Component and High-Intensity 20 Hz Repetitive Transcranial Magnetic Stimulation—A Pilot Study," IJERPH, MDPI, vol. 18(21), pages 1-12, October.
  • Handle: RePEc:gam:jijerp:v:18:y:2021:i:21:p:11224-:d:664889
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/18/21/11224/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/18/21/11224/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:18:y:2021:i:21:p:11224-:d:664889. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.