IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v18y2021i18p9812-d637943.html
   My bibliography  Save this article

Removal of Arsenic Oxyanions from Water by Ferric Chloride—Optimization of Process Conditions and Implications for Improving Coagulation Performance

Author

Listed:
  • Muhammad Ali Inam

    (Institute of Environmental Sciences and Engineering (IESE), School of Civil and Environmental Engineering (SCEE), H-12 Campus, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan)

  • Rizwan Khan

    (Department of Chemical Engineering, Quaid-e-Awam University of Engineering, Science and Technology (QUEST), Nawabshah 67480, Pakistan)

  • Kang-Hoon Lee

    (Department of Civil and Environmental Engineering, Hanyang University, Seoul 04763, Korea)

  • Young-Min Wie

    (Department of Materials Engineering, Kyonggi University, Suwon 16227, Korea)

Abstract

The chronic ingestion of arsenic (As) contaminated water has raised significant health concerns worldwide. Iron-based coagulants have been widely used to remove As oxyanions from drinking water sources. In addition, the system’s ability to lower As within the maximum acceptable contamination level (MCL) is critical for protecting human health from its detrimental effects. Accordingly, the current study comprehensively investigates the performance of As removal under various influencing factors including pH, contact time, temperature, As (III, V) concentration, ferric chloride (FC) dose, and interfering ions. The optimum pH for As (V) removal with FC was found to be pH 6–7, and it gradually decreased as the pH increased. In contrast, As (III) removal increased with an increase in pH with an optimum pH range of 7–10. The adsorption of As on precipitated iron hydroxide (FHO) was better fitted with pseudo-second order and modified Langmuir–Freundlich models. The antagonistic effect of temperature on As removal with FC was observed, with optimum temperature of 15–25 °C. After critically evaluating the optimum operating conditions, the uptake indices of both As species were developed to select appropriate an FC dose for achieving the MCL level. The results show that the relationship between residual concentration, FC dose, and adsorption affinity of the system was well represented by uptake indices. The higher FC dose was required for suspensions containing greater concentration of As species to achieve MCL level. The As (V) species with a greater adsorption affinity towards FHO require a relatively smaller FC dose than As (III) ions. Moreover, the significant influence of interfering species on As removal was observed in simulated natural water. The author hopes that this study may help researchers and the drinking water industry to develop uptake indices of other targeted pollutants in achieving MCL level during water treatment operations in order to ensure public health safety.

Suggested Citation

  • Muhammad Ali Inam & Rizwan Khan & Kang-Hoon Lee & Young-Min Wie, 2021. "Removal of Arsenic Oxyanions from Water by Ferric Chloride—Optimization of Process Conditions and Implications for Improving Coagulation Performance," IJERPH, MDPI, vol. 18(18), pages 1-13, September.
  • Handle: RePEc:gam:jijerp:v:18:y:2021:i:18:p:9812-:d:637943
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/18/18/9812/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/18/18/9812/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:18:y:2021:i:18:p:9812-:d:637943. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.