Abstract

Building renovations can adversely affect building occupants through the release of biological contaminants, gases and particulates. In this study, the research aim was to monitor the air quality of a renovated building and assess the impact of sick building syndrome (SBS) on the occupants. Post occupancy monitoring of the building was carried out after two months occupancy for the following environmental parameters: airborne microflora using an air sampler (SAS super 180) and a hand-held monitoring device (Graywolf advance sense IQ-610) to measure total volatile organic compounds (TVOC), CO 2 , CO and temperature and relative humidity in each office environment. In addition, an online (Qualtrics) structured questionnaire was used to assess occupants’ perceptions of the indoor environment. Results of the airborne flora showed 833 cfu/m 3 recovered on a Malt Extract Agar (MEA) plate in the morning and 1213 cfu/m 3 in the afternoon. A similar result was noticed on a Plate Count Agar (PCA) plate during the morning period (731 cfu/m 3 ) and afternoon (1358 cfu/m 3 ). Results of TVOC monitored over one week showed that the first two days of monitoring had a high reading that peaked at 10,837 ppb and that the CO 2 concentration during that period was 1163 ppm. Online questionnaire analysis indicates that a majority of the staff who took part in the survey experienced some form of health abnormality, including headache, shortness of breath, itchy eyes/ears, loss of concentration and so on, especially in the first few weeks of returning to the office. The results from the study indicate that a large proportion (41%) of the respondents experienced thermal discomfort as a result of varying room temperature during their working hours. A high number of female participants experienced some form of SBS as compared to their male counterparts. The study findings show a direct relationship between high airborne mold counts, TVOC and adverse staff health perception of the building. The study raised a number of opportunities for estate managers to improve building performance based on occupants’ preferences.

Suggested Citation

  • Haya Fahad Alomirah & Haruna Musa Moda, 2020. "Assessment of Indoor Air Quality and Users Perception of a Renovated Office Building in Manchester," IJERPH, MDPI, vol. 17(6), pages 1-9, March.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:6:p:1972-:d:333528
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/6/1972/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/6/1972/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Haruna Musa Moda & Debrah King, 2019. "Assessment of Occupational Safety and Hygiene Perception among Afro-Caribbean Hair Salon Operators in Manchester, United Kingdom," IJERPH, MDPI, vol. 16(18), pages 1-12, September.
    2. Marco Gola & Gaetano Settimo & Stefano Capolongo, 2019. "Chemical Pollution in Healing Spaces: The Decalogue of the Best Practices for Adequate Indoor Air Quality in Inpatient Rooms," IJERPH, MDPI, vol. 16(22), pages 1-15, November.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Della Egfors & Anita Gidlöf Gunnarsson & Niklas Ricklund, 2022. "Changes in Reported Symptoms Attributed to Office Environments in Sweden between 1995 and 2020," IJERPH, MDPI, vol. 19(18), pages 1-14, September.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Sanja Kezic & Roberto Nunez & Željka Babić & Sarah Hallmann & Martin S. Havmose & Jeanne D. Johansen & Swen M. John & Marija Macan & Cara Symanzik & Wolfgang Uter & Patricia Weinert & Rajka Turk & Jel, 2022. "Occupational Exposure of Hairdressers to Airborne Hazardous Chemicals: A Scoping Review," IJERPH, MDPI, vol. 19(7), pages 1-20, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:6:p:1972-:d:333528. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.