IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i2p412-d306378.html
   My bibliography  Save this article

Analytical Bias in the Measurement of Plasma 25-Hydroxyvitamin D Concentrations in Infants

Author

Listed:
  • Kristina Rueter

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia
    Perth Children’s Hospital, Department of Paediatric Immunology, Perth 6009, Australia
    inVIVO Planetary Health, Group of the Worldwide Universities Network (WUN), West New York, NJ 07093, USA)

  • Lucinda J. Black

    (School of Public Health, Curtin University, Perth 6102, Australia)

  • Anderson Jones

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia
    Telethon Kids Institute, University of Western Australia, Perth 6009, Australia)

  • Max Bulsara

    (Institute for Health Research, University of Notre Dame, Fremantle 6160, Australia)

  • Michael W. Clarke

    (Metabolomics Australia, Centre for Microscopy, Characterisation and Analysis, The University of Western Australia, Perth 6009, Australia)

  • Cristina Gamez

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia)

  • Ee M. Lim

    (Sir Charles Gairdner Hospital, Department of Endocrinology, Perth 6009, Australia
    PathWest Laboratory Medicine, QEII Medical Centre, Nedlands 6009, Australia)

  • Debra J. Palmer

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia
    Telethon Kids Institute, University of Western Australia, Perth 6009, Australia)

  • Susan L. Prescott

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia
    Perth Children’s Hospital, Department of Paediatric Immunology, Perth 6009, Australia
    Telethon Kids Institute, University of Western Australia, Perth 6009, Australia)

  • Aris Siafarikas

    (Division of Paediatrics, School of Medicine, The University of Western Australia, Perth 6009, Australia
    Telethon Kids Institute, University of Western Australia, Perth 6009, Australia
    Institute for Health Research, University of Notre Dame, Fremantle 6160, Australia
    Perth Children’s Hospital, Department of Paediatric Endocrinology and Diabetes, Perth 6009, Australia)

Abstract

Hypovitaminosis D is prevalent worldwide; however, analytical bias in the measurement of circulating 25-hydroxyvitamin D (25(OH)D) concentrations may affect clinical treatment decisions and research. We performed parallel plasma 25(OH)D analyses using the Abbott Architect i2000 chemiluminescent immunoassay (CIA) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) for paired samples from the same infants at 3 ( n = 69), 6 ( n = 79) and 12 months ( n = 73) of age. To test agreement, we used Lin’s concordance correlation coefficient and corresponding 95% confidence interval, Bland–Altman’s limits of agreement, and Bradley–Blackwood (BB) test. Agreement was high at 3 months (coefficient between difference and mean −0.076; BB F = 0.825; p = 0.440), good at 12 months (−0.25; BB F = 2.41; p = 0.097) but missing at 6 months of age (−0.39; BB F = 12.30; p < 0.001). Overall, 18 infants had disparate results based on the cut-off point for vitamin D deficiency (25(OH)D < 50 nmol/L), particularly at three months, with seven (10%) infants deficient according to CIA but not LC–MS/MS, and four (6%) deficient by LC–MS/MS but not CIA. To our knowledge, this is the first study to show that the reported 25(OH)D concentration may be influenced by both age and assay type. Physicians and researchers should be aware of these pitfalls when measuring circulating 25(OH)D concentrations in infants and when developing treatment plans based on measured vitamin D status.

Suggested Citation

  • Kristina Rueter & Lucinda J. Black & Anderson Jones & Max Bulsara & Michael W. Clarke & Cristina Gamez & Ee M. Lim & Debra J. Palmer & Susan L. Prescott & Aris Siafarikas, 2020. "Analytical Bias in the Measurement of Plasma 25-Hydroxyvitamin D Concentrations in Infants," IJERPH, MDPI, vol. 17(2), pages 1-12, January.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:2:p:412-:d:306378
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/2/412/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/2/412/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:2:p:412-:d:306378. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.