IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i22p8585-d447457.html
   My bibliography  Save this article

Improvement of Ficin-Based Inhibitive Enzyme Assay for Toxic Metals Using Response Surface Methodology and Its Application for Near Real-Time Monitoring of Mercury in Marine Waters

Author

Listed:
  • Garba Uba

    (Department of Science Laboratory Technology, College of Science and Technology, Jigawa State Polytechnic, Dutse PMB 7040, Nigeria)

  • Motharasan Manogaran

    (Department of Biochemistry, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, Serdang 43400 UPM, Selangor, Malaysia)

  • Baskaran Gunasekaran

    (Faculty of Applied Science, UCSI University, 56000 Kuala Lumpur, Selangor, Malaysia)

  • Mohd Izuan Effendi Halmi

    (Department of Land Management, Faculty of Agriculture, University Putra Malaysia, Serdang 43400 UPM Selangor, Malaysia)

  • Mohd Yunus Abd Shukor

    (Department of Biochemistry, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, Serdang 43400 UPM, Selangor, Malaysia)

Abstract

Potentially toxic metals pollution in the Straits of Malacca warrants the development of rapid, simple and sensitive assays. Enzyme-based assays are excellent preliminary screening tools with near real-time potential. The heavy-metal assay based on the protease ficin was optimized for mercury detection using response surface methodology. The inhibitive assay is based on ficin action on the substrate casein and residual casein is determined using the Coomassie dye-binding assay. Toxic metals strongly inhibit this hydrolysis. A central composite design (CCD) was utilized to optimize the detection of toxic metals. The results show a marked improvement for the concentration causing 50% inhibition (IC 50 ) for mercury, silver and copper. Compared to one-factor-at-a-time (OFAT) optimization, RSM gave an improvement of IC 50 (mg/L) from 0.060 (95% CI, 0.030–0.080) to 0.017 (95% CI, 0.016–0.019), from 0.098 (95% CI, 0.077–0.127) to 0.028 (95% CI, 0.022–0.037) and from 0.040 (95% CI, 0.035–0.045) to 0.023 (95% CI, 0.020–0.027), for mercury, silver and copper, respectively. A near-real time monitoring of mercury concentration in the Straits of Malacca at one location in Port Klang was carried out over a 4 h interval for a total of 24 h and validated by instrumental analysis, with the result revealing an absence of mercury pollution in the sampling site.

Suggested Citation

  • Garba Uba & Motharasan Manogaran & Baskaran Gunasekaran & Mohd Izuan Effendi Halmi & Mohd Yunus Abd Shukor, 2020. "Improvement of Ficin-Based Inhibitive Enzyme Assay for Toxic Metals Using Response Surface Methodology and Its Application for Near Real-Time Monitoring of Mercury in Marine Waters," IJERPH, MDPI, vol. 17(22), pages 1-15, November.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:22:p:8585-:d:447457
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/22/8585/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/22/8585/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:22:p:8585-:d:447457. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.