IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i22p8569-d447307.html
   My bibliography  Save this article

An Improved Passive CR-39-Based Direct 222 Rn/ 220 Rn Progeny Detector

Author

Listed:
  • Jun Hu

    (Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan)

  • Guosheng Yang

    (National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan)

  • Chutima Kranrod

    (Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan)

  • Kazuki Iwaoka

    (National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan)

  • Masahiro Hosoda

    (Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan
    Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan)

  • Shinji Tokonami

    (Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Japan)

Abstract

An improved passive CR-39-based direct 222 Rn/ 220 Rn progeny detector with 3 detection channels was designed and tested in this study to measure and calculate equilibrium equivalent concentration (EEC) of both 222 Rn and 220 Rn without the equilibrium factor. A theoretical model was established to calculate the EEC with optimization. Subsequently, an exposure experiment was carried out to test the performance of this detector, and we compared the chamber experiment and the theoretical model by estimating and measuring various parameters. The deposition flux of progeny derived from the prediction agreed well with the value measured in the exposure chamber. The energy-weighted net track density (NTD) measured by this detector is much more reliable to reflect the linear relation between NTD and time-integrated EEC. Since the detector is sensitive to the exposure environmental condition, it is recommended to apply the detector to measure the EEC after its calibration in a typical indoor environment.

Suggested Citation

  • Jun Hu & Guosheng Yang & Chutima Kranrod & Kazuki Iwaoka & Masahiro Hosoda & Shinji Tokonami, 2020. "An Improved Passive CR-39-Based Direct 222 Rn/ 220 Rn Progeny Detector," IJERPH, MDPI, vol. 17(22), pages 1-13, November.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:22:p:8569-:d:447307
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/22/8569/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/22/8569/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:22:p:8569-:d:447307. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.