IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i21p7845-d435045.html
   My bibliography  Save this article

A Novel Method for Gait Analysis on Center of Pressure Excursion Based on a Pressure-Sensitive Mat

Author

Listed:
  • Eun-tae Jeon

    (Department of Health Science, Gachon University Graduate School, Incheon 21936, Korea
    Department of Neurology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea
    Medical Science Research Center, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355, Korea)

  • Hwi-young Cho

    (Department of Health Science, Gachon University Graduate School, Incheon 21936, Korea
    Department of Physical Therapy, Gachon University, Incheon 21936, Korea)

Abstract

Center of pressure (COP) during gait is a useful measure for assessing gait ability and has been investigated using platform or insole systems. However, these systems have inherent restrictions in repeated measure design or in obtaining true vertical force. This study proposes a novel method based on a pressure-sensitive mat system for COP measurement and presents normal reference values for the system. To explore repeatability, this work also investigated relative and absolute intra-rater reliabilities and determined the number of footfalls required to obtain a reliable measurement. Ninety healthy young adults participated and performed barefoot walking on a force-sensitive mat at a comfortable and fast pace. The time points and subphase duration of the stance phase, displacement ranges, and mean locations of COP and velocity of COP excursion were parameterized. The results showed acceptable and consistent variabilities of the parameters. Seven footfalls were determined as the threshold for most parameters to show a good to reasonable level of reliability. In conclusion, the presented method can be used as a reliable measurement for COP excursion, and it is recommended that more than seven footfalls be collected to ensure a high level of reliability.

Suggested Citation

  • Eun-tae Jeon & Hwi-young Cho, 2020. "A Novel Method for Gait Analysis on Center of Pressure Excursion Based on a Pressure-Sensitive Mat," IJERPH, MDPI, vol. 17(21), pages 1-14, October.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:21:p:7845-:d:435045
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/21/7845/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/21/7845/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:21:p:7845-:d:435045. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .