IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2019i1p54-d299998.html
   My bibliography  Save this article

Simulation of Air Puff Tonometry Test Using Arbitrary Lagrangian–Eulerian (ALE) Deforming Mesh for Corneal Material Characterisation

Author

Listed:
  • Osama Maklad

    (School of Engineering, University of Liverpool, Liverpool L69 3GH, UK)

  • Ashkan Eliasy

    (School of Engineering, University of Liverpool, Liverpool L69 3GH, UK)

  • Kai-Jung Chen

    (School of Engineering, University of Liverpool, Liverpool L69 3GH, UK)

  • Vassilios Theofilis

    (School of Engineering, University of Liverpool, Liverpool L69 3GH, UK)

  • Ahmed Elsheikh

    (School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
    NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London EC1V 9EL, UK
    School of Biological Science and Biomedical Engineering, Beihang University, Beijing 100191, China)

Abstract

Purpose: To improve numerical simulation of the non-contact tonometry test by using arbitrary Lagrangian-Eulerian deforming mesh in the coupling between computational fluid dynamics model of an air jet and finite element model of the human eye. Methods: Computational fluid dynamics model simulated impingement of the air puff and employed Spallart–Allmaras model to capture turbulence of the air jet. The time span of the jet was 30 ms and maximum Reynolds number was R e = 2.3 × 10 4 , with jet orifice diameter 2.4 mm and impinging distance 11 mm. The model of the human eye was analysed using finite element method with regional hyperelastic material variation and corneal patient-specific topography starting from stress-free configuration. The cornea was free to deform as a response to the air puff using an adaptive deforming mesh at every time step of the solution. Aqueous and vitreous humours were simulated as a fluid cavity filled with incompressible fluid with a density of 1000 kg/m 3 . Results: Using the adaptive deforming mesh in numerical simulation of the air puff test improved the traditional understanding of how pressure distribution on cornea changes with time of the test. There was a mean decrease in maximum pressure (at corneal apex) of 6.29 ± 2.2% and a development of negative pressure on a peripheral corneal region 2–4 mm away from cornea centre. Conclusions: The study presented an improvement of numerical simulation of the air puff test, which will lead to more accurate intraocular pressure (IOP) and corneal material behaviour estimation. The parametric study showed that pressure of the air puff is different from one model to another, value-wise and distribution-wise, based on cornea biomechanical parameters.

Suggested Citation

  • Osama Maklad & Ashkan Eliasy & Kai-Jung Chen & Vassilios Theofilis & Ahmed Elsheikh, 2019. "Simulation of Air Puff Tonometry Test Using Arbitrary Lagrangian–Eulerian (ALE) Deforming Mesh for Corneal Material Characterisation," IJERPH, MDPI, vol. 17(1), pages 1-21, December.
  • Handle: RePEc:gam:jijerp:v:17:y:2019:i:1:p:54-:d:299998
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/1/54/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/1/54/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2019:i:1:p:54-:d:299998. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.