IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v15y2018i6p1277-d152889.html
   My bibliography  Save this article

Lateral Sinus Floor Elevation Performed with Trapezoidal and Modified Triangular Flap Designs: A Randomized Pilot Study of Post-Operative Pain Using Thermal Infrared Imaging

Author

Listed:
  • Antonio Scarano

    (Department of Medical, Oral and Biotechnological Sciences and CeSi-Met, ‘G. D’Annunzio’ University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy)

  • Felice Lorusso

    (Department of Medical, Oral and Biotechnological Sciences University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy)

  • Merla Arcangelo

    (Department of Neuroscience, Imaging and Clinical Sciences, ‘G. D’Annunzio’ University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy)

  • Camillo D’Arcangelo

    (Department of Medical, Oral and Biotechnological Sciences and CeSi-Met, ‘G. D’Annunzio’ University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy)

  • Renato Celletti

    (Department of Medical, Oral and Biotechnological Sciences and CeSi-Met, ‘G. D’Annunzio’ University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy)

  • Pablo Santos De Oliveira

    (Department of Oral Implantology, Dental Research Division, College Ingà, UNINGÁ, 29312 Cachoeiro de Itapemirim, Espirito Santo, Brazil)

Abstract

Purpose: Post-operative pain and swelling are frequently observed after sinus lift procedures. The aim of the present study was the clinical evaluation of swelling and pain of two different sinus flap lift techniques using a visual analogue scale (VAS), verbal rating scale (VRS), and infrared thermal imaging (i.e., thermography). Materials Methods : A randomized controlled trial was conducted with 15 patients (30 sinuses in total) randomly allocated into two groups. For the sinuses of Group I a trapezoidal flap was used, while for Group II a modified triangular flap without anterior release was utilized. Postoperative pain was scored by means of a 100-mm VAS ranging from 0 (no pain) to 100 (worst pain imaginable), and was recorded at 2, 4, 6 and 14 days after surgery. Swelling was recorded by a verbal rating scale (VRS) and was classified into four categories: a score of 1 referred the absence of swelling, patients with intra-oral swelling in the surgical zone scored 2, any extra-oral swelling in the surgical zone scored 3, and intense swelling exhibited by extra-oral swelling extending beyond the surgical zone scored 4. The facial temperature was recorded before and after sinus augmentation, and at 2, 4, 6, and 14 days post-surgery to check the course of healing. Results : In Group I pain intensity was recorded at 2 days after surgery with a mean score of 38.67 ± 6.4 mm. Swelling was greater at 2 and 4 days, and was absent at day 6. The facial temperature difference before and after the procedure was 4.737 °C ± 0.37. In Group II the pain score were lower than in Group I ( p < 0.05). The score for swelling was 2 on the first and second days, and was reduced on day 4. After the second day the difference in temperature was significantly reduced as compared to the day of surgery (0.77 °C); at 2 and 4 days no difference was registered. Conclusions : The results of this clinical study show the significant effectiveness of the modified triangular flap in the sinus lift procedure for reducing pain and swelling.

Suggested Citation

  • Antonio Scarano & Felice Lorusso & Merla Arcangelo & Camillo D’Arcangelo & Renato Celletti & Pablo Santos De Oliveira, 2018. "Lateral Sinus Floor Elevation Performed with Trapezoidal and Modified Triangular Flap Designs: A Randomized Pilot Study of Post-Operative Pain Using Thermal Infrared Imaging," IJERPH, MDPI, vol. 15(6), pages 1-13, June.
  • Handle: RePEc:gam:jijerp:v:15:y:2018:i:6:p:1277-:d:152889
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/15/6/1277/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/15/6/1277/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Antonio Scarano & Francesco Inchingolo & Felice Lorusso, 2020. "Facial Skin Temperature and Discomfort When Wearing Protective Face Masks: Thermal Infrared Imaging Evaluation and Hands Moving the Mask," IJERPH, MDPI, vol. 17(13), pages 1-9, June.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:15:y:2018:i:6:p:1277-:d:152889. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.