IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v15y2018i11p2335-d177667.html
   My bibliography  Save this article

Portable Analyzer for On-Site Determination of Dissolved Organic Carbon—Development and Field Testing

Author

Listed:
  • Heinrich Glorian

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

  • Viktor Schmalz

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

  • Paweł Lochyński

    (Institute of Environmental Engineering, Wrocław University of Environmental and Life Sciences, 50-375 Wrocław, Poland)

  • Paul Fremdling

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

  • Hilmar Börnick

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

  • Eckhard Worch

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

  • Thomas Dittmar

    (Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany)

Abstract

Dissolved organic carbon (DOC) is a sum parameter that is frequently used in water analytics. Highly resolved and accurate DOC data are necessary, for instance, for water quality monitoring and for the evaluation of the efficiency of treatment processes. The conventional DOC determination methods consist of on-site sampling and subsequent analysis in a stationary device in a laboratory. However, especially in regions where no or only poorly equipped laboratories are available, this method bears the risk of getting erroneous results. For this reason, the objective of the present study was to set up a reliable and portable DOC analyzer for on-site analysis. The presented DOC system is equipped with an electrolysis-based decomposition cell with boron-doped diamond electrodes (BDD) that oxidizes the organic compounds to carbon dioxide. Within this study, the influence of different electrode materials and the composition of the applied electrolytes on the DOC decomposition in an undivided electrolytic cell were systematically investigated. Furthermore, some technical aspects of the portable prototype are discussed. After a detailed validation, the prototype was used in an ongoing monitoring program in Northern India. The limit of detection is 0.1 mg L −1 C with a relative standard deviation of 2.3% in a linear range up to 1000 mg L C −1 . The key features of the portable DOC analyzer are: No need for ultra-pure gases, catalysts or burning technology, an analyzing time per sample below 5 min, and a reliable on-site DOC determination.

Suggested Citation

  • Heinrich Glorian & Viktor Schmalz & Paweł Lochyński & Paul Fremdling & Hilmar Börnick & Eckhard Worch & Thomas Dittmar, 2018. "Portable Analyzer for On-Site Determination of Dissolved Organic Carbon—Development and Field Testing," IJERPH, MDPI, vol. 15(11), pages 1-13, October.
  • Handle: RePEc:gam:jijerp:v:15:y:2018:i:11:p:2335-:d:177667
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/15/11/2335/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/15/11/2335/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:15:y:2018:i:11:p:2335-:d:177667. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.