IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v19y2026i16p3751-d2012307.html

Energy-Efficiency-Constrained Diffusion Model for High-Energy-Consumption Anomaly Diagnosis in Slab Reheating Furnaces

Author

Listed:
  • Shuqi He

    (School of Mathematics and Computer Science, Panzhihua University, Panzhihua 617000, China)

  • Jing Zhang

    (School of Mathematics and Computer Science, Panzhihua University, Panzhihua 617000, China)

  • Yong Liu

    (Pangang Group Panzhihua Steel and Vanadium Co., Ltd., Panzhihua 617000, China)

  • Chao Deng

    (Pangang Group Panzhihua Steel and Vanadium Co., Ltd., Panzhihua 617000, China)

  • Hao Wu

    (Pangang Group Panzhihua Steel and Vanadium Co., Ltd., Panzhihua 617000, China)

Abstract

Slab reheating furnaces are among the most energy-intensive units in hot-rolling production lines, and their operating states directly affect fuel consumption, temperature uniformity, and production cost. High energy consumption conditions often arise from coupled changes in reheating time, furnace-temperature regulation, combustion status, and production rhythm, making them difficult to identify using fixed energy thresholds or manual experience alone. This study proposes an energy-efficiency-constrained DDPM-ConvTransformer method for data-driven high-energy-consumption anomaly diagnosis in slab reheating furnaces. Continuous industrial records are converted into fixed-length production windows, and a denoising diffusion probabilistic model is used to learn the multivariate temporal distribution of normal operating conditions. A convolutional module and a Transformer encoder are embedded in the denoising network to capture local thermal-process fluctuations and long-range temporal dependencies. During training, a specific-energy auxiliary constraint guides the shared representation toward operating patterns associated with energy efficiency. During inference, window-level anomaly scores are obtained from diffusion denoising errors, and the decision threshold is determined from validation-set score quantiles. Using 7476 industrial production records for model development and evaluation, the test-set results show that the detected abnormal windows have 47.83% higher specific energy consumption and 62.17% higher total energy consumption than normal windows, with Cohen’s d values of 1.27 and 1.60, respectively. Compared with PCA, Isolation Forest, autoencoder-based models, an energy-constrained Transformer autoencoder, and diffusion-based baselines, the proposed method produces stronger post hoc energy-consumption differences, while computational cost analysis further clarifies its practical trade-off for offline diagnosis and periodic screening. Group analysis, typical-window diagnosis, and perturbation validation further support its applicability for energy-efficiency diagnosis and high-consumption operating-condition screening in slab reheating furnaces.

Suggested Citation

  • Shuqi He & Jing Zhang & Yong Liu & Chao Deng & Hao Wu, 2026. "Energy-Efficiency-Constrained Diffusion Model for High-Energy-Consumption Anomaly Diagnosis in Slab Reheating Furnaces," Energies, MDPI, vol. 19(16), pages 1-32, August.
  • Handle: RePEc:gam:jeners:v:19:y:2026:i:16:p:3751-:d:2012307
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/19/16/3751/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/19/16/3751/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:19:y:2026:i:16:p:3751-:d:2012307. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.