Author
Listed:
- Peng Jia
(Economic Research Institute of State Grid Henan Electric Power Company, Zhengzhou 450052, China)
- Yun Sun
(School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China)
- Linlin Yu
(Economic Research Institute of State Grid Henan Electric Power Company, Zhengzhou 450052, China)
- Jing Zhang
(School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China)
- Xiaoliang Jiang
(Economic Research Institute of State Grid Henan Electric Power Company, Zhengzhou 450052, China)
- Gaojun Meng
(School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China)
Abstract
Existing approaches insufficiently analyze the quantitative relationship between frequency stability indices and wind power penetration rates. This limitation impedes rapid and accurate assessments of wind power’s grid integration potential. This paper first analyzed the impact mechanism of wind power integration on system inertia and static power-frequency characteristics from different aspects of the influence of double-fed induction generators (DFIGs) on the operating modes of synchronous machines. Subsequently, based on this analysis, the paper derived the quantitative relationship between key indicators reflecting transient frequency response characteristics during power shortages and wind power penetration rates. It also rapidly calculated the maximum wind power penetration rate based on constraints of frequency change rate and maximum frequency deviation, thereby enabling a quantitative evaluation of wind power grid connection capability. Finally, the IEEE 39-bus test system was used for case analysis. The research results indicate that the proposed method can accurately quantify the impact of wind power variation on system frequency stability and rapidly determine the maximum wind power penetration rate to ensure frequency stability, thereby improving the accuracy of the wind power grid connection capability assessment.
Suggested Citation
Peng Jia & Yun Sun & Linlin Yu & Jing Zhang & Xiaoliang Jiang & Gaojun Meng, 2025.
"Research on the Frequency Stability Analysis of Grid-Connected Double-Fed Induction Generator Systems,"
Energies, MDPI, vol. 18(9), pages 1-16, April.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:9:p:2170-:d:1641164
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:9:p:2170-:d:1641164. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.