Abstract
The present paper provides a general overview of the state of the art of steam generating heat pumps (SGHPs) technology employed in the industrial field. Recommended best practices and optimization procedures for overall performance improvement of compression closed-loop-based systems are described in detail, as well as the main modifications of the thermodynamic heat pump cycle. Once the main configurations of SGHPs are described, the different concepts are compared in terms of supply temperature ranges; cases of comparison among different concepts are reviewed, and techno-economic barriers are also discussed. The working fluids (including natural refrigerants) commonly selected for these steam generating systems are presented along with their uses. Moreover, zeotropic refrigerant mixtures and new potentially usable mixtures are mentioned. After that, refrigerant selection criteria for high temperature heat pumps are also discussed. Then, using an internal heat exchanger, refrigerant injection technique and super heating in lubricated compressors are herein presented as best practices for general performance improvement. Regarding thermodynamic cycle modifications, basic auto-cascade and quasi-two-stage compression cycles are discussed along with further improvements suggested in the specialized literature. Lastly, optimization strategies useful to enhance the heat pumps’ design and based on TOPSIS method, advanced exergy analysis, exergy-based cost minimization and combined design are analyzed.
Suggested Citation
Giampaolo D’Alessandro & Marco Iezzi & Filippo de Monte, 2025.
"Steam Generating High Temperature Heat Pumps: Best Practices, Optimization Strategies and Refrigerant Selection for Performance Improvement,"
Energies, MDPI, vol. 18(22), pages 1-32, November.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:22:p:5879-:d:1790241
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:22:p:5879-:d:1790241. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager The email address of this maintainer does not seem to be valid anymore. Please ask MDPI Indexing Manager to update the entry or send us the correct address
(email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.