Abstract
Distributed photovoltaic grid-connected converters adopting droop control can provide dual support for voltage and frequency in the distribution system. However, under fault conditions, droop-controlled inverters will face the problem of transient synchronization instability, and their transient characteristics are significantly affected by fault conditions, control parameter configurations, and other factors. Nevertheless, at present, the transient operation boundaries of droop inverters, considering key sensitive parameters, are unclear, and the transient stability control mechanism is lacking, which poses a threat to the safe and stable operation of distributed photovoltaic systems. To this end, this paper fully considers the influences of control parameters and fault severity and conducts a multidimensional quantitative characterization of the transient stability boundaries of droop-controlled inverters. Furthermore, a stability enhancement control structure for droop-controlled inverters, based on power angle deviation feedforward, is proposed, and an adaptive configuration method for feedforward coefficients is put forward to ensure the safe and stable operation of droop inverters at different fault sag depths. Finally, the accuracy of the theoretical analysis and the proposed control structure is verified through simulations and experiments.
Suggested Citation
Youzhuo Zheng & Zekun Xiao & Long Hua & Qi Guo & Chun Li & Kailei Chen, 2025.
"Transient Stability Control Method for Droop-Controlled Photovoltaics, Based on Power Angle Deviation Feedback,"
Energies, MDPI, vol. 18(19), pages 1-15, September.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:19:p:5126-:d:1759071
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:19:p:5126-:d:1759071. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.