Author
Listed:
- Song Zhang
(Guizhou Electric Power Research Institute, China Southern Power Grid, Guiyang 546000, China)
- Xiaobin Xiao
(Guizhou Electric Power Research Institute, China Southern Power Grid, Guiyang 546000, China)
- Lei Jia
(Power Research Institute, China Southern Power Grid, Guangzhou 510530, China)
- Huaifei Chen
(Power Research Institute, China Southern Power Grid, Guangzhou 510530, China)
- Lu Qu
(Power Research Institute, China Southern Power Grid, Guangzhou 510530, China)
- Chakhung Yeung
(Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom 999077, Hong Kong)
- Yuxuan Ding
(Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom 999077, Hong Kong)
- Yaping Du
(Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom 999077, Hong Kong)
Abstract
Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards.
Suggested Citation
Song Zhang & Xiaobin Xiao & Lei Jia & Huaifei Chen & Lu Qu & Chakhung Yeung & Yuxuan Ding & Yaping Du, 2025.
"Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network,"
Energies, MDPI, vol. 18(19), pages 1-17, September.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:19:p:5097-:d:1757881
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:19:p:5097-:d:1757881. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.