Author
Listed:
- Seong-Gwang Kim
(Research and Development Headquarters, Hudius, 50, Cheomdangwagi-ro 208beon-gil, Buk-gu, Gwangju 61012, Republic of Korea)
- Byung-Ik Jung
(Department of AI Convergence Electrical Engineering, Donggang University, 50, Dongmundaero, Buk-gu, Gwangju 61200, Republic of Korea)
- Ju-Ho Park
(Department of Fire Protection and Disaster Management, Chosun University, 30, Chosundae 3-gil, Dong-gu, Gwangju 61452, Republic of Korea)
- Yeo-Gyeong Lee
(Department of Fire Protection and Disaster Management, Chosun University, 30, Chosundae 3-gil, Dong-gu, Gwangju 61452, Republic of Korea)
- Sang-Yong Park
(Department of Fire Protection and Disaster Management, Chosun University, 30, Chosundae 3-gil, Dong-gu, Gwangju 61452, Republic of Korea)
Abstract
Insulation degradation in photovoltaic (PV) cables can cause electrical faults and fire hazards, thereby compromising system reliability and safety. Early detection of precursor signals is crucial for preventive maintenance. However, conventional diagnostic techniques are limited to static assessments and fail to capture early-stage electrical anomalies in real-time. This study investigates the time-series behavior of voltage, current, and temperature in PV cables under thermal stress conditions. Experiments were conducted using TFR-CV cables installed in a vertically stacked and tight-contact configuration. A gas torch was applied for localized heating to induce insulation degradation. A grid-connected testbed with six series-connected PV modules was constructed. Each module was instrumented with PV-M sensors, temperature sensors, and an infrared camera. Data were acquired at 1 Hz intervals. Results showed that cable surface temperature exceeded 280 °C during degradation. The output voltage exhibited transient surges of up to +13.3% and drops of −68%, while the output current decreased by over 20%, particularly in the PV-M3 module. These anomalies, such as thermal imbalance, voltage spikes/dips, and current drops, were closely associated with critical degradation points and are interpreted as precursor signals. This work confirms the feasibility of identifying fire-related precursors through real-time monitoring of PV cable electrical characteristics. The observed correlation between electrical responses and thermal expansion behaviors suggests a strong link to the stages of insulation degradation. Future work will focus on quantifying the relationship between degradation and electrical behavior under controlled environmental conditions.
Suggested Citation
Seong-Gwang Kim & Byung-Ik Jung & Ju-Ho Park & Yeo-Gyeong Lee & Sang-Yong Park, 2025.
"Analysis of Photovoltaic Cable Degradation and Fire Precursor Signals for Optimizing Integrated Power Grids,"
Energies, MDPI, vol. 18(19), pages 1-18, September.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:19:p:5087-:d:1757398
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:19:p:5087-:d:1757398. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.