IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v18y2025i16p4267-d1721998.html
   My bibliography  Save this article

Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements

Author

Listed:
  • Hao Sheng

    (Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China)

  • Siqi Zhang

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Tianqi Zhao

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Jing Hao

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Qi Li

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Guangming Xin

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Rui Chen

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Xiaofei Wang

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

  • Xiang Ren

    (Electric Power Research Institute, State Grid Jibei Electric Power Company Limited, Beijing 100045, China)

Abstract

The large-scale integration of renewable energy and the high penetration of power electronic devices have led to a significant reduction in system inertia and short-circuit capacity. This is particularly manifested in the form of insufficient multiple renewable energy stations short-circuit ratio (MRSCR) and transient overvoltage issues following severe disturbances such as AC and DC faults, which greatly limit the power transfer capability of large renewable energy bases. To effectively mitigate these challenges, this paper proposes an optimal synchronous condenser deployment method tailored for large-scale renewable energy bases. The proposed mathematical model supports a hybrid centralized and distributed configuration of synchronous condensers with various capacities and manufacturers while considering practical engineering constraints such as short-circuit ratio, transient overvoltage, and available bays in renewable energy stations. A practical decomposition and iterative computation strategy is introduced to reduce the computational burden of transient stability simulations. Case studies based on a real-world system verify the effectiveness of the proposed method in determining the optimal configuration of synchronous condensers. The results demonstrate significant improvements in grid strength (MRSCR) and suppression of transient overvoltages, thereby enhancing the stability and transfer capability of renewable energy bases in weak-grid environments.

Suggested Citation

  • Hao Sheng & Siqi Zhang & Tianqi Zhao & Jing Hao & Qi Li & Guangming Xin & Rui Chen & Xiaofei Wang & Xiang Ren, 2025. "Optimal Synchronous Condenser Placement in Renewable Energy Bases to Meet Renewable Energy Transfer Capacity Requirements," Energies, MDPI, vol. 18(16), pages 1-16, August.
  • Handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4267-:d:1721998
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/18/16/4267/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/18/16/4267/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:16:p:4267-:d:1721998. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.