IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v18y2025i14p3782-d1703373.html
   My bibliography  Save this article

Application of Ice Slurry as a Phase Change Material in Mine Air Cooling System—A Case Study

Author

Listed:
  • Łukasz Mika

    (Department of Thermal and Fluid Flow Machines, Faculty of Energy and Fuels, AGH University of Krakow, al. A. Mickiewicza 30, 30-059 Krakow, Poland)

  • Karol Sztekler

    (Department of Thermal and Fluid Flow Machines, Faculty of Energy and Fuels, AGH University of Krakow, al. A. Mickiewicza 30, 30-059 Krakow, Poland)

  • Ewelina Radomska

    (Department of Thermal and Fluid Flow Machines, Faculty of Energy and Fuels, AGH University of Krakow, al. A. Mickiewicza 30, 30-059 Krakow, Poland)

Abstract

Fossil fuels, including coal, are a basis of energy systems in many countries worldwide. However, coal mining is associated with several difficulties, which include high temperatures within the coal mining area. It causes a need for cooling for safety reasons and also for the comfort of miners’ work. Typical cooling systems in mines are based on central systems, in which chilled water is generated in the compressor or absorption coolers on the ground and transported via pipelines to the air coolers in the areas of mining. The progressive mining operation causes a gradual increase in the distance between chilled water generators and air coolers, causing a decrease in the efficiency of the entire system and insufficient cooling capacity. As a result, it is necessary to increase the diameter of the chilled water pipelines and increase the cooling capacity of the chillers, which is associated with additional investment and technical problems. One solution to this problem may be the use of so-called ice slurry instead of chilled water in the existing mine cooling system. This article presents the cooling system, located in the mine LW Bogdanka S.A., based on ice slurry. The structure of the system and its key parameters are presented. The results show that switching from cooling water to ice slurry allowed the cooling capacity of the entire system to increase by 50% while maintaining the existing piping. This demonstrates the very high potential for the use of ice slurry, not only in mines, but wherever further increases in piping diameters to maintain the required cooling capacity are not possible or cost-effective.

Suggested Citation

  • Łukasz Mika & Karol Sztekler & Ewelina Radomska, 2025. "Application of Ice Slurry as a Phase Change Material in Mine Air Cooling System—A Case Study," Energies, MDPI, vol. 18(14), pages 1-19, July.
  • Handle: RePEc:gam:jeners:v:18:y:2025:i:14:p:3782-:d:1703373
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/18/14/3782/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/18/14/3782/
    Download Restriction: no
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:14:p:3782-:d:1703373. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.