Author
Listed:
- Yujia Tang
(State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
National Energy Power Grid Technology R&D Centre, Guangzhou 510663, China
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou 510663, China)
- Xin Zhou
(Yunnan Power Grid Co., Ltd., Electric Power Research Institute, Kunming 650217, China)
- Yihua Zhu
(State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
National Energy Power Grid Technology R&D Centre, Guangzhou 510663, China
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou 510663, China)
- Junzhen Peng
(Yunnan Power Grid Co., Ltd., Electric Power Research Institute, Kunming 650217, China)
- Chao Luo
(State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
National Energy Power Grid Technology R&D Centre, Guangzhou 510663, China
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou 510663, China)
- Li Zhang
(Yunnan Power Grid Co., Ltd., Electric Power Research Institute, Kunming 650217, China)
- Jinling Qi
(State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou 510663, China
National Energy Power Grid Technology R&D Centre, Guangzhou 510663, China
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou 510663, China)
Abstract
With the large-scale integration of photovoltaic power plants—comprising power electronic devices—into power systems, electromagnetic transient simulation has become a key tool for ensuring power system security and stability. The accuracy of photovoltaic unit controller parameters is crucial for the reliability of such simulations. However, as the issue of sub/super-synchronous oscillations becomes increasingly prominent, existing parameter identification methods are primarily based on high/low voltage ride-through characteristics. This limits the applicability of the identification results to specific scenarios and lacks targeted simulation and parameter identification research for sub/super-synchronous oscillations. To address this gap, this study proposes a mathematical model tailored for sub/super-synchronous oscillations and performs sensitivity analysis of converter control parameters to identify dominant parameters across different frequency bands. A frequency-segmented parameter identification method is introduced, capable of fast convergence without relying on a specific optimization algorithm. Finally, the proposed method’s identification results are compared with actual values, voltage ride-through-based identification, particle swarm optimization results, and results under uncertain conditions. It was found that, compared with traditional identification methods, the proposed method reduced the maximum identification error from 7.67% to 4.3% and the identification time from 2 h to 1 h. The maximum identification error of other intelligent algorithms was 5%, with a difference of less than 1% compared to the proposed method. The identified parameters were applied under conditions of strong irradiation (1000 W/m 2 ), weak irradiation (300 W/m 2 ), rapidly varying oscillation frequency, and constant oscillation frequency, and the output characteristics were all close to those of the original parameters. The effectiveness and superiority of the proposed method have been validated, along with its broad applicability to different intelligent algorithms and its robustness under uncertain conditions such as environmental variations and grid frequency fluctuations.
Suggested Citation
Yujia Tang & Xin Zhou & Yihua Zhu & Junzhen Peng & Chao Luo & Li Zhang & Jinling Qi, 2025.
"Impedance Characteristic-Based Frequency-Domain Parameter Identification Method for Photovoltaic Controllers,"
Energies, MDPI, vol. 18(12), pages 1-19, June.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:12:p:3118-:d:1678572
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:12:p:3118-:d:1678572. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.