Abstract
Low-frequency power oscillations (LFPOs) may occur in voltage source converter-based high-voltage direct current (VSC-HVDC) systems when providing frequency support to asynchronously interconnected power grids. This phenomenon has been observed in the LUXI back-to-back (BTB) VSC-HVDC project in China and results from insufficient damping, which may threaten the stability of the overall power system. To better understand and address this problem, this study investigates the root causes of LFPOs and evaluates how different parts of the system affect damping. A combined approach using small-signal modeling and the damping torque method is developed to analyze the damping behavior of DC power in VSC-HVDC systems. Results show that LFPOs are caused by the interaction between VSC-based frequency control and the dynamic response of synchronous generators (SGs). The turbine and governor systems in SGs help stabilize the system by providing positive damping, whereas the DC voltage-controlled VSC station introduces negative damping. The findings are supported by detailed simulations using a modified IEEE 39-bus test system, demonstrating the effectiveness of the proposed analysis method.
Suggested Citation
Ke Wang & Chunguang Zhou & Yiping Chen & Yan Guo & Zhantao Fan & Zhixuan Li, 2025.
"Investigation of Frequency Response Sharing-Induced Power Oscillations in VSC-HVDC Systems for Asynchronous Interconnection,"
Energies, MDPI, vol. 18(11), pages 1-23, June.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:11:p:2928-:d:1670905
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:11:p:2928-:d:1670905. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.