Author
Listed:
- Zheng Wang
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Hua Zhang
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Yiyang Zhang
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Haoyong Zhang
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Jing Chen
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Shuting Feng
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Jie Guo
(Langfang Power Supply Company, State Grid Jibei Electric Power Company Limited, Langfang 065000, China)
- Yanpeng Lv
(School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou 450000, China)
Abstract
The contact condition of circuit breaker contacts directly affects their operational reliability, while circuit resistance, as a key performance indicator, reflects physical changes such as wear, oxidation, and ablation. Traditional offline measurement methods fail to accurately represent the real-time operating state of equipment due to large errors and high randomness, limiting their effectiveness for state awareness and precision maintenance. To address this, a non-contact multi-sensor fusion method for the online monitoring of circuit breaker circuit resistance is proposed, aimed at enhancing operational state awareness in power systems. The method integrates Hall effect current sensors, infrared temperature sensors, and electric field sensors to extract multiple sensing signals, combined with high-precision signal processing algorithms to enable the real-time identification and evaluation of circuit resistance changes. Experimental validation under various scenarios—including normal load, overload impact, and high-temperature and high-humidity environments—demonstrates excellent system performance, with a fast response time (≤200 ms), low measurement error (<1.5%), and strong anti-interference capability (SNR > 60 dB). In field applications, the system successfully identifies circuit resistance increases caused by contact oxidation and issues early warnings, thereby preventing unplanned outages and demonstrating a strong potential for application in the fault prediction and intelligent maintenance of power grids.
Suggested Citation
Zheng Wang & Hua Zhang & Yiyang Zhang & Haoyong Zhang & Jing Chen & Shuting Feng & Jie Guo & Yanpeng Lv, 2025.
"A Study on Non-Contact Multi-Sensor Fusion Online Monitoring of Circuit Breaker Contact Resistance for Operational State Awareness,"
Energies, MDPI, vol. 18(10), pages 1-19, May.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:10:p:2667-:d:1661215
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:10:p:2667-:d:1661215. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.