In order to reduce the sampling delay and improve bandwidth, sability margin, and the robustness of the active damping in LCL-filtered grid-connected inverters, real-time sampling provides a convenient method. However, aliasing is easily introduced in the control loop because of high-frequency switching harmonics, resulting in a rise in low-order harmonics. To address the challenge of aliasing under real-time sampling, a new method based on multisampling and mean filtering is proposed by combining the proposed harmonic detection and control methods in this paper. This method works by sampling and controlling the fundamental current and selective subharmonic currents separately. The fundamental current control loop without any additional filters maintains real-time sampling, while multisampling and mean filters are applied to the harmonic current control loop. The proposed control method can not only improve the dynamic response performance and control stability of the system but also effectively suppress the selective low-order current harmonics and the aliasing of sampling. Finally, the correctness of the proposed sampling scheme and control strategy is verified by the simulation based on R2018b, MathWorks, Natick, MA, USA and an experimental prototype of a three-phase grid-connected photovoltaic inverter rated at 230 V/50 Hz/40 kW.

Suggested Citation

  • Houlai Geng & Yunfeng Xu & Weimin Wu, 2024. "Aliasing Suppression Method for a Three-Phase Grid-Connected Photovoltaic Inverter Based on Multi-Sampling and Mean Filtering," Energies, MDPI, vol. 17(4), pages 1-15, February.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:4:p:907-:d:1339344
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/4/907/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/4/907/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:4:p:907-:d:1339344. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.