IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i4p1713-d1062460.html
   My bibliography  Save this article

Electrical Event Detection and Monitoring Data Storage from Wide Area Measurement System

Author

Listed:
  • Vinicius Tertulino Parede

    (Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil)

  • Alexandre Rasi Aoki

    (Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil)

  • Mateus Duarte Teixeira

    (Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil)

  • Thelma S. Piazza Fernandes

    (Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil)

  • Nathan Elias Maruch Barreto

    (Department of Electrical Engineering, Federal University of Parana, Curitiba 81531-990, PR, Brazil)

  • Flavio Lori Grando

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Vanderlei Aparecido da Silva

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Fabio Alessandro Guerra

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Milton Pires Ramos

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Clayton Hilgemberg da Costa

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Bruna Machado Mulinari

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Germano Lambert-Torres

    (Institute Gnarus, Itajubá 81070-190, MG, Brazil)

  • Ricardo Rodrigues de Almeida

    (Copel Generation and Transmission S.A, Curitiba 81200-240, PR, Brazil)

  • Rafael Rodrigues

    (Copel Generation and Transmission S.A, Curitiba 81200-240, PR, Brazil)

  • Victor Frederico Müller Junior

    (Copel Generation and Transmission S.A, Curitiba 81200-240, PR, Brazil)

  • André Katayama dos Santos

    (Copel Generation and Transmission S.A, Curitiba 81200-240, PR, Brazil)

Abstract

Synchronized phasor measurement systems are being widely used around the world and have become essential elements in the evolution of the operation of large electrical power systems (EPS). These systems, called Phasor Measurement Units (PMUs), are capable of recording and communicating dynamic data from the EPSs in a synchronized way by GPS and with a high sampling rate, generate a huge set of data that, among many applications, has the capacity to detect events. In this way, this work presents a data management system architecture applied to a real PMU system located in the state of Paraná, Brazil that detects and storages events using principal component analysis and Pearson correlation. This method can detect and store electrical events that occurred during the operation of the national interconnected system of Brazil with good results.

Suggested Citation

  • Vinicius Tertulino Parede & Alexandre Rasi Aoki & Mateus Duarte Teixeira & Thelma S. Piazza Fernandes & Nathan Elias Maruch Barreto & Flavio Lori Grando & Vanderlei Aparecido da Silva & Fabio Alessand, 2023. "Electrical Event Detection and Monitoring Data Storage from Wide Area Measurement System," Energies, MDPI, vol. 16(4), pages 1-17, February.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1713-:d:1062460
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/4/1713/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/4/1713/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1713-:d:1062460. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.