IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i4p1596-d1058551.html
   My bibliography  Save this article

Calculation of AC Losses in a 500 kJ/200 kW Multifilamentary MgB 2 SMES Coil

Author

Listed:
  • Antonio Morandi

    (Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy)

  • Massimo Fabbri

    (Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy)

  • Pier Luigi Ribani

    (Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy)

  • Francesco Lo Franco

    (Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy)

  • Riccardo Mandrioli

    (Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy)

  • Umberto Melaccio

    (ASG Superconductors—Columbus MgB 2 Unit, Via delle Terre Rosse 30, 16133 Genoa, Italy)

  • Daniele Magrassi

    (ASG Superconductors—Columbus MgB 2 Unit, Via delle Terre Rosse 30, 16133 Genoa, Italy)

  • Martina Neri

    (ASG Superconductors—Columbus MgB 2 Unit, Via delle Terre Rosse 30, 16133 Genoa, Italy)

  • Alessio Capelluto

    (ASG Superconductors—Columbus MgB 2 Unit, Via delle Terre Rosse 30, 16133 Genoa, Italy)

  • Matteo Tropeano

    (ASG Superconductors—Columbus MgB 2 Unit, Via delle Terre Rosse 30, 16133 Genoa, Italy)

  • Chiara Gandolfi

    (Transmission and Distribution Department, Ricerca sul Sistema Energetico SpA, Via R. Rubattino 54, 20134 Milan, Italy)

Abstract

SMES technology based on MgB 2 superconductor and cryogenic-free cooling can offer a viable solution to power-intensive storage in the short term. One of the main obstacles to the development of dry-cooled SMES systems is the heat load removal due to the AC loss of the superconductor during fast charging and discharging cycles at high power. Accurate knowledge of the amount and distribution of AC loss in the coil is of paramount importance for the sizing and the design of the cooling system and for assessing the possible operational limits of the technology. In this manuscript, the AC loss of a 500 kJ/200 kW multifilamentary MgB 2 SMES during charge–discharge cycling at full power is numerically investigated. The methodology and assumptions of the calculation are briefly resumed, and numerical results are reported and discussed in detail. In particular, the time profile and the distribution of the dissipated power all over the coil are reported. An average dissipation of 85.5 mW/m is found all over the coil during one charge–discharge cycle at full power, with a peak of 150.1 mW/m in the turns lying at the ends of the coil.

Suggested Citation

  • Antonio Morandi & Massimo Fabbri & Pier Luigi Ribani & Francesco Lo Franco & Riccardo Mandrioli & Umberto Melaccio & Daniele Magrassi & Martina Neri & Alessio Capelluto & Matteo Tropeano & Chiara Gand, 2023. "Calculation of AC Losses in a 500 kJ/200 kW Multifilamentary MgB 2 SMES Coil," Energies, MDPI, vol. 16(4), pages 1-20, February.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1596-:d:1058551
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/4/1596/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/4/1596/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1596-:d:1058551. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.