IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i23p7769-d1287711.html
   My bibliography  Save this article

The Mitigation of Interference on Underground Power Lines Caused by the HVDC Electrode

Author

Listed:
  • Massimo Brignone

    (Electrical, Electronics and Telecommunication Engineering and Naval Architecture Department, University of Genoa, Via All’Opera Pia 11, 16145 Genoa, Italy)

  • Daniele Mestriner

    (Electrical, Electronics and Telecommunication Engineering and Naval Architecture Department, University of Genoa, Via All’Opera Pia 11, 16145 Genoa, Italy)

  • Paolo Molfino

    (Electrical, Electronics and Telecommunication Engineering and Naval Architecture Department, University of Genoa, Via All’Opera Pia 11, 16145 Genoa, Italy)

  • Mario Nervi

    (Electrical, Electronics and Telecommunication Engineering and Naval Architecture Department, University of Genoa, Via All’Opera Pia 11, 16145 Genoa, Italy)

  • Massimo Marzinotto

    (TERNA S.p.A., 00185 Roma, Italy)

  • Sino Patti

    (TERNA S.p.A., 00185 Roma, Italy)

Abstract

High Voltage Direct Current power links are usually designed to adopt, on a continuous basis or during emergency operations, two grounding plants using the soil or seawater as a link–current return path. Such DCs flowing into the ground can cause problems, of which one of the most important is the increased risk of the corrosion of metallic structures in the area. Normally, the simplest mitigation technique is to keep an adequate distance between the main grounding plants and any metallic structure that can be corroded. Normally, such distances are not less than 5 km. However, there are situations where this approach cannot be applied, for example due to geographical constraints. In this paper, we describe and analyze the behavior of a mitigation technique that can be adopted when the HV pole cable is laid closer than the recommended distance to the main ground electrode. This paper is focused on the minimization of deleterious effects on the cable’s metallic sheath and its earthing points, distributed along it by means of sheath segmentation. The suggested approach appears well-suited to substantially diminishing the current flowing through the sheath of an HVDC power cable. In the segmented scenario, the sheath’s power dissipation is less than one-hundredth of that in the typical continuous configuration.

Suggested Citation

  • Massimo Brignone & Daniele Mestriner & Paolo Molfino & Mario Nervi & Massimo Marzinotto & Sino Patti, 2023. "The Mitigation of Interference on Underground Power Lines Caused by the HVDC Electrode," Energies, MDPI, vol. 16(23), pages 1-10, November.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:23:p:7769-:d:1287711
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/23/7769/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/23/7769/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:23:p:7769-:d:1287711. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.