IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i22p7463-d1275327.html
   My bibliography  Save this article

Flat-Plate PHP with Gravity-Independent Performance and High Maximum Thermal Load

Author

Listed:
  • Markus Winkler

    (Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-Köhler-Allee 301, 79110 Freiburg, Germany)

  • Marc Vergez

    (Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-Köhler-Allee 301, 79110 Freiburg, Germany)

  • Andreas Mahlke

    (Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-Köhler-Allee 301, 79110 Freiburg, Germany)

  • Mathias Gebauer

    (Fraunhofer Institute for Machine Tools and Forming Technology IWU, Nöthnitzer Str. 44, 01187 Dresden, Germany)

  • Phillip Müller

    (Fraunhofer Institute for High Frequency Physics and Radar Techniques FHR, Fraunhoferstraße 20, 53343 Wachtberg, Germany)

  • Christoph Reising

    (Fraunhofer Institute for High Frequency Physics and Radar Techniques FHR, Fraunhoferstraße 20, 53343 Wachtberg, Germany)

  • Kilian Bartholomé

    (Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-Köhler-Allee 301, 79110 Freiburg, Germany)

  • Olaf Schäfer-Welsen

    (Fraunhofer Institute for Physical Measurement Techniques IPM, Georges-Köhler-Allee 301, 79110 Freiburg, Germany)

Abstract

In many energy-related applications, components with high heat loads, such as power electronics, play an important role. Pulsating heat pipes (PHPs) are an effective solution to deal with the increasing heat load of these components. In many real-life applications, the PHP must work against gravity and still be able to operate efficiently. However, the majority of present flat-plate PHP designs do not perform well under this condition. Therefore, this paper presents a flat-plate PHP with a conventional channel design optimized for gravity-independent operation. The PHP was capable of transmitting a heat output of 754 watts in all orientations, while the testing heater in use never exceeded a temperature of 100 °C. No indications of dryout were observed, implying that the maximum thermal load the PHP can handle is even higher. Additionally, three different condenser zone sizes were tested with the PHP. Previously published results indicated that there is a specific range of suitable condenser zone sizes, and performance problems will occur if the condenser zone size falls outside of this range. The findings from this work point in the same direction.

Suggested Citation

  • Markus Winkler & Marc Vergez & Andreas Mahlke & Mathias Gebauer & Phillip Müller & Christoph Reising & Kilian Bartholomé & Olaf Schäfer-Welsen, 2023. "Flat-Plate PHP with Gravity-Independent Performance and High Maximum Thermal Load," Energies, MDPI, vol. 16(22), pages 1-18, November.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:22:p:7463-:d:1275327
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/22/7463/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/22/7463/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:22:p:7463-:d:1275327. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.