IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i19p6790-d1246600.html
   My bibliography  Save this article

Indoor Climate Monitoring in Office Buildings—Comparative Analysis of Two Office Buildings without Air Conditioning

Author

Listed:
  • Karsten Voss

    (Faculty of Architecture and Civil Engineering, University of Wuppertal, Pauluskirchstr. 7, D-42285 Wuppertal, Germany)

  • Tjado Voß

    (Faculty of Architecture and Civil Engineering, University of Wuppertal, Pauluskirchstr. 7, D-42285 Wuppertal, Germany)

  • Marvin Kaliga

    (Faculty of Architecture and Civil Engineering, University of Wuppertal, Pauluskirchstr. 7, D-42285 Wuppertal, Germany)

Abstract

Against the background of climate protection and the rising costs of a fossil-fuel-based energy supply, the interest in the energy performance and indoor climate of buildings in real operation is rising. This paper, therefore, deals with the indoor climate investigation of two medium-sized office buildings in Germany by taking measurements over a whole year. These relate to one new building and one refurbished building. Sensors of various types were installed and operated in a large number of office rooms, so that in total results are available for over 100 rooms, typically occupied by one or two persons. The analysis focuses on the indoor temperature in summer and the air quality in winter based on the CO 2 concentration. The comfort classes according to DIN EN 16798 including the adaptive comfort approach are used as a basis to cluster the results. Both buildings have movable sun protection and openable windows but no facilities for active cooling. They, thus, represent a large number of existing ‘low tech’ office buildings in Germany and central Europe. The results reflect the respective building concepts but also show a wide range between the rooms due to the user preferences and behaviour. The refurbished building shows better results, especially in terms of air quality but also in terms of summer room temperatures. This underlines the benefit of the targeted measures as a result of an analysis of the deficits in the existing building before the refurbishment. The additional measures for decentralised mechanical ventilation and passive cooling are having positive effects. As part of the projects, further measures to improve the indoor climate were investigated in both buildings. In one case, this involved CO 2 traffic lights to stimulate personal window ventilation in winter, and in the other, the use of newly developed individual ceiling fans supports convective heat dissipation on the human body during hot spells in summer. The positive effect could be demonstrated for both measures.

Suggested Citation

  • Karsten Voss & Tjado Voß & Marvin Kaliga, 2023. "Indoor Climate Monitoring in Office Buildings—Comparative Analysis of Two Office Buildings without Air Conditioning," Energies, MDPI, vol. 16(19), pages 1-17, September.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:19:p:6790-:d:1246600
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/19/6790/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/19/6790/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:19:p:6790-:d:1246600. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.