LED lamps have gradually replaced other lighting sources and have become mainstream in the lighting industry. The research on interharmonic sensitivity affecting their lighting quality cannot be ignored. By deconstructing the lamp-eye-brain module in the International Electrotechnical Commission (IEC) flicker model, a luminous flux flicker model without the constraints of a specific light source was proposed. The test system and corresponding analysis method of the interharmonic-luminous flux transfer coefficient in the model were described in detail, and the accuracy of the test results of the system was verified via incandescent lamp heat balance model simulations. Based on the test results, the conversion method of the interharmonic ratio of LED lamps under the flicker limit based on the interharmonic-flicker limit curve of incandescent lamps was deduced. By testing and comparing the differences in interharmonic-flicker limit curves of different driving types of LED lamps, the experimental evaluation of their sensitivity was completed, and the reference for LED lamp selection, driver design, and compatibility standard formulation in different application scenarios was provided.

Suggested Citation

  • Hongtao Li & Yifan Song & Mingxing Zhu & Yadong Jiao, 2022. "Experimental Interharmonic Sensitivity Evaluation of LED Lamps Based on the Luminous Flux Flicker Model," Energies, MDPI, vol. 15(9), pages 1-14, April.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:9:p:2990-:d:797364
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/9/2990/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/9/2990/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:9:p:2990-:d:797364. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.