IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i22p8727-d978473.html
   My bibliography  Save this article

Reduced Sensor Based Control of PV-DSTATCOM with Switch Current Limiting Scheme

Author

Listed:
  • Pragnyashree Ray

    (Department of Electrical Engineering, National Institute of Technology, Rourkela 769008, India)

  • Pravat Kumar Ray

    (Department of Electrical Engineering, National Institute of Technology, Rourkela 769008, India)

  • Mousa Marzband

    (Department of Mathematics, Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK
    Center of Research Excellence in Renewable Energy and Power Systems, King Abdulaziz University, Jeddah 21589, Saudi Arabia)

Abstract

The work delineated in this paper deals with the reduced sensor-based operation of PV-DSTATCOM (Photovoltaic distribution static compensator) focusing on the voltage source inverter (VSI) switch current limiting control. In this study, the soft computing technique of PV-DSTATCOM control based on the variable leaky least mean square (VLLMS) algorithm is modified to incorporate both reduced sensor and switch current limiting schemes. DSTATCOM is predominantly introduced to improve current related power quality issues by providing non-real power (i.e., the reactive and harmonic component) of the load demand. However, during uncertain increase in the non-real power requirement at the load end due to sudden change in the load demand or any other transient conditions, the non-real current injected by the DSTATCOM may increase to a level which is beyond the current handling capacity of the DSTATCOM switches. As a consequence, the switches may become permanently damaged and, subsequently, the performance of the DSTATCOM will deteriorate. Hence, the current through the VSI switches can be limited by controlling the amount of non-real power flow from the DSTATCOM. During this transient or high current condition, the control transits from power quality improvement mode to protection mode. As a result, unity power factor operation at P.C.C (common point of coupling) is compromised for that period or few cycles of transient condition. Moreover, the efficient operation of any control demands proper information about the current and the voltage of the system, which are determined by sensors. However, the faults in these sensors may deteriorate the controller performance and degrade the system efficacy. Therefore, to mitigate this issue, the numbers of measurement units are reduced i.e., the measurement of current in only two phases for load as well as grid, and the measurement of line voltages using two voltage sensors instead of three sensors for each phase. The reduction of sensors is accomplished without compromising the controller efficiency. Further, the system is studied using MATLAB/Simulink under different condition of steady- state, varying solar irradiance, increasing load above rated capacity.

Suggested Citation

  • Pragnyashree Ray & Pravat Kumar Ray & Mousa Marzband, 2022. "Reduced Sensor Based Control of PV-DSTATCOM with Switch Current Limiting Scheme," Energies, MDPI, vol. 15(22), pages 1-17, November.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:22:p:8727-:d:978473
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/22/8727/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/22/8727/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:22:p:8727-:d:978473. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.