IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i21p8012-d955950.html
   My bibliography  Save this article

Research on the Thermal Stratification Phenomenon at the Secondary Side of a Steam Generator in an Isolated Loop

Author

Listed:
  • Xinxin Liu

    (College of Nuclear Science and Technology, Naval University of Engineering, Wuhan 430033, China)

  • Lei Yu

    (College of Nuclear Science and Technology, Naval University of Engineering, Wuhan 430033, China)

  • Jianli Hao

    (College of Nuclear Science and Technology, Naval University of Engineering, Wuhan 430033, China
    Nuclear Power Institute of China, Chengdu 610041, China)

  • Wenzhen Chen

    (College of Nuclear Science and Technology, Naval University of Engineering, Wuhan 430033, China)

Abstract

In normal operation, there is no significant thermal stratification phenomenon in the tube bundle area of the steam generator of the nuclear power plant. However, this phenomenon is detected in marine nuclear power plant isolation loops in the presence of feedwater leakage. Therefore, an experiment was designed to verify the presence of thermal stratification, and the influence factors were analyzed by the RELAP5/MOD3.2 program. The results show that thermal stratification is mainly influenced by the initial water level at isolation, the initial pressure at isolation, the total leakage mass, and the internal circulation of the steam generator. Leakage flow has little effect on it. This phenomenon causes the coolant temperature at the primary side of the steam generator in the isolated loop to be lower than the temperature measured in the reactor inlet pipe or outlet pipe. This study aids the operator in determining the real coolant temperature at the primary side of the steam generator in the isolated loop and prevents reactivity insertion accidents when the isolated loop is put into operation.

Suggested Citation

  • Xinxin Liu & Lei Yu & Jianli Hao & Wenzhen Chen, 2022. "Research on the Thermal Stratification Phenomenon at the Secondary Side of a Steam Generator in an Isolated Loop," Energies, MDPI, vol. 15(21), pages 1-11, October.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:8012-:d:955950
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/21/8012/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/21/8012/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:8012-:d:955950. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.