Abstract

This paper presents a novel hardware-in-the-loop (HIL) approach as used to investigate the impact of the reduction in inertia on the Great Britain (GB) electrical power system with regard to rate of change of frequency (RoCoF) settings for Loss-of-Mains (LoM) protection. Furthermore, the research as presented in this paper updates, enhances, and validates a reduced model of the Great Britain transmission system, as originally developed in DIgSILENT PowerFactory by the National Grid Electricity System Operator. The enhanced model has been developed for integrated use with the OPAL-RT real-time HIL simulation toolkit and is validated against phasor measurement unit (PMU) data from actual disturbance events using novel automated interfacing between both integrated simulation platforms, PowerFactory from DIgSILENT and ePHASORSIM from OPAL-RT. The corresponding simulations show that the updated reduced model is capable of capturing the dynamic behaviour of the GB transmission system, including both local and inter-area oscillations, with satisfactory accuracy. Finally, the paper presents HIL study results with the reduced model to investigate the influence of decreasing system inertia on the response of LoM protection relays. The studies show that decreasing system inertia may have a significant impact on LoM relays using RoCoF detection, particularly relays using the legacy G59 setting of 0.125 Hz/s. Initial studies have also demonstrated the potential for a previously unrecognised interaction between system oscillations and the 500 ms operating delay, as specified in G59 and G99 Engineering Recommendations. Consequently, faster local oscillations (>1 Hz) reset the relay and decrease the sensitivity, whereas slower inter-area oscillations (<1 Hz) appear to cause the relay to overestimate the average RoCoF.

Suggested Citation

  • Peter Imris & Gareth A. Taylor & Martin E. Bradley & Yun Li, 2022. "A Novel Hardware-in-the-Loop Approach to Investigate the Impact of Low System Inertia on RoCoF Relay Settings," Energies, MDPI, vol. 15(17), pages 1-23, September.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:17:p:6386-:d:903894
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/17/6386/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/17/6386/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:17:p:6386-:d:903894. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.