IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i11p3887-d823366.html
   My bibliography  Save this article

Fault-Tolerant Control for Reducing Harmonic Distortion of Dual Three-Phase Permanent Magnet Synchronous Motor

Author

Listed:
  • Liping Zhao

    (School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China
    School of Automation, Harbin University of Science and Technology, Harbin 150080, China)

  • Baojun Ge

    (School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China)

  • Hanying Gao

    (School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China)

  • Dajun Tao

    (School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China)

Abstract

Aiming at the open circuit fault of a dual three-phase permanent magnet synchronous motor, a normalized current method is used for open circuit fault diagnosis. Then, a fault-tolerant control strategy for reducing the harmonic distortion of a dual three-phase permanent magnet synchronous motor is proposed, which is based on current model prediction control and keeps the decoupling transformation matrix unchanged. The fault-tolerant control method based on current model prediction considers the influence of the control quantity on the future state of the system, and effectively reduces the total harmonic distortion. Two fault-tolerant control strategies for the motor are analyzed, with minimizing stator copper consumption and maximizing torque output as control objectives. Through simulation and experiment of fault-tolerant control strategies for a dual three-phase permanent magnet synchronous motor, the results verify the effectiveness and feasibility of the strategy.

Suggested Citation

  • Liping Zhao & Baojun Ge & Hanying Gao & Dajun Tao, 2022. "Fault-Tolerant Control for Reducing Harmonic Distortion of Dual Three-Phase Permanent Magnet Synchronous Motor," Energies, MDPI, vol. 15(11), pages 1-20, May.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:11:p:3887-:d:823366
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/11/3887/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/11/3887/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:11:p:3887-:d:823366. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.