Abstract
This paper presents a new soft-switching solution recommended for three-level neutral-point-clamped inverters. The operation principles of the proposed solution, working stages, selection of elements, and the control algorithm are comprehensively discussed herein. The control method of the inverter main switches is the same as that of the switches of an inverter operating according to the hard-switching technique. The correctness of the proposed solution was confirmed by the results of different tests using a laboratory neutral-point-clamped inverter with rated parameters of 3 kW, 2 × 150 V, 12 A, and 3 kHz. Numerical analyses were performed for the inverter of rated power 1.2 MW. The switching losses of the inverter operating with the proposed solution were compared with those of an inverter with hard-switching method. The proposed soft-switching solution increased the inverter efficiency and its competitiveness in relation to other proposals because there were no connections between switches and capacitors or inductors, which pose a risk of damaging the inverter when disturbances in the control system appear.
Suggested Citation
Zbigniew Szular & Bartosz Rozegnal & Witold Mazgaj, 2021.
"A New Soft-Switching Solution in Three-Level Neutral-Point-Clamped Voltage Source Inverters,"
Energies, MDPI, vol. 14(8), pages 1-23, April.
Handle:
RePEc:gam:jeners:v:14:y:2021:i:8:p:2247-:d:537833
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:8:p:2247-:d:537833. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.