IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i7p1906-d526902.html
   My bibliography  Save this article

Transition Planes for Visual Comfort: Out View with Complex Fenestration System Design at Restaurants in Spain

Author

Listed:
  • Urtza Uriarte

    (Department of Architecture, University of the Basque Country UPV/EHU, Plaza Oñati 2, 20018 Donostia-San Sebastián, Spain)

  • Jose Miguel Rico-Martinez

    (Department of Architecture, University of the Basque Country UPV/EHU, Plaza Oñati 2, 20018 Donostia-San Sebastián, Spain)

  • Joan L. Zamora

    (Architecture Technology Department, Universitat Politècnica de Catalunya·Barcelona-Tech, Av. Diagonal 649-651, 08028 Barcelona, Spain)

  • Rufino J. Hernández

    (Department of Architecture, University of the Basque Country UPV/EHU, Plaza Oñati 2, 20018 Donostia-San Sebastián, Spain)

Abstract

This work deals with daylighting for quality indoor atmospheres, considering building skins. In recent years, almost all retrofit facades of restaurants are highly glazed façades, boosting glare, sun ray absorption and overheating inside. Most of the time, they are not integrated with daylight control; therefore, lighting and out view requirements are not so balanced. Taking into account this daylighting complexity, an alternative façade system is proposed to simulate by Radiance. Previously, perception simulations are compared with measured data, in order to discretize the simulations. In addition, for one point three different view are assessed as: work plane, relation plane and the out plane. Subsequently, two virtual façade models, windows combined by complex fenestration system (CFS) as prismatic film (PF) and highly glazed façade, are tested according to daylighting. For that, three indexes have been used: daylight glare probability (DGP), daylight glare index (DGI) and daylight autonomy (DA). The results show that the proposed complex façade has a good light contribution with less absorption, while maintaining the outside view. In addition, the DGI is needed to test the out plane, because DGP is more suitable for lower luminance; therefore, each visual plane should be assessed regarding different visual comfort conditions, or parameters and methods. Accordingly, the mean DGI result of window combined by CFS is approximately lower in 5% than highly glazed façade. However, the DA of highly glazed is higher in 5%, but the DA of window combined by CFS is enough, above 80%. Definitely, the complex scene at restaurant with the proposed integrated façade system improves light performance and indoor atmosphere.

Suggested Citation

  • Urtza Uriarte & Jose Miguel Rico-Martinez & Joan L. Zamora & Rufino J. Hernández, 2021. "Transition Planes for Visual Comfort: Out View with Complex Fenestration System Design at Restaurants in Spain," Energies, MDPI, vol. 14(7), pages 1-17, March.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:7:p:1906-:d:526902
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/7/1906/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/7/1906/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:7:p:1906-:d:526902. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.