IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v14y2021i4p867-d495232.html
   My bibliography  Save this article

An Experimental Study of In-Tube Condensation and Evaporation Using Enhanced Heat Transfer (EHT) Tubes

Author

Listed:
  • Boren Zheng

    (Department of Energy Engineering, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310027, China)

  • Jiacheng Wang

    (Department of Mechanical and Electrical Engineering, Qingdao University of Science and Technology, 99 Songling Road, Qingdao 266061, China)

  • Yu Guo

    (Department of Mechanical and Electrical Engineering, Qingdao University of Science and Technology, 99 Songling Road, Qingdao 266061, China)

  • David John Kukulka

    (Department of Mechanical Engineering Technology, State University of New York College at Buffalo, 1300 Elmwood Avenue, Buffalo, NY 14222, USA)

  • Weiyu Tang

    (Department of Energy Engineering, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310027, China)

  • Rick Smith

    (Rigidized Metals Corporation, Vipertex Division, 658 Ohio Street, Buffalo, NY 14203, USA)

  • Zhichuan Sun

    (AVIC Nanjing Engineering Institute of Aircraft Systems, Nanjing 211106, China
    Aviation Key Laboratory of Science and Technology on Aero Electromechanical System Integration, Nanjing 211106, China)

  • Wei Li

    (Department of Energy Engineering, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310027, China)

Abstract

A study was carried out to determine in-tube evaporation and condensation performance of enhanced heat transfer tubes (EHT) using R410A, with the results being compared to a plain tube. The test tubes considered in the evaluation include: plain, herringbone (HB) and spiral (HX) microgrooves, herringbone dimple (HB/D), and hydrophobic herringbone (HB/HY). Experiments to evaluate the condensation were conducted at a saturation of 318 K, and at 279 K for evaporation. Mass flux (G) ranged between 40 to 230 kg m −2 s −1 . Condensed vapor mass decreased from 0.8 to 0.2; and the mass of vaporized vapor increases from 0.2 to 0.8; heat flux increased with G. Inlet and outlet two-phase flow patterns at 200 kg m −2 s −1 were recorded and analyzed. Enhanced tube heat transfer condensation performance (compared to a plain tube) increased in the range from 40% to 73%. The largest heat transfer increase is produced by the herringbone–dimple tube (HB/D). In addition to providing drainage, the herringbone groove also helps to lift the accumulated condensate to wet the surrounding wall. Evaporation thermal performance of the enhanced tubes are from 4% to 46% larger than that of smooth tube with the best performance being in the hydrophobic herringbone tube (HB/HY). This enhancement can be attributed to an increase in the number of nucleation sites and a larger heat transfer surface area. Evaporation and condensation correlations for heat transfer in smooth tubes is discussed and compared.

Suggested Citation

  • Boren Zheng & Jiacheng Wang & Yu Guo & David John Kukulka & Weiyu Tang & Rick Smith & Zhichuan Sun & Wei Li, 2021. "An Experimental Study of In-Tube Condensation and Evaporation Using Enhanced Heat Transfer (EHT) Tubes," Energies, MDPI, vol. 14(4), pages 1-15, February.
  • Handle: RePEc:gam:jeners:v:14:y:2021:i:4:p:867-:d:495232
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/14/4/867/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/14/4/867/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Yu Gao & Hong Cheng & Wei Li & David John Kukulka & Rick Smith, 2022. "Condensation Flow and Heat Transfer Characteristics of R410A in Micro-Fin Tubes and Three-Dimensional Surface Enhanced Tubes," Energies, MDPI, vol. 15(8), pages 1-20, April.
    2. Xu Wang & David John Kukulka & Xiang-Zeng Liu & Wei Feng & Xiao-Bo Wang & Wei Li & Ze-Peng Wang, 2023. "Evaporation Flow Heat Transfer Characteristics of Stainless Steel and Copper Enhanced Tubes," Energies, MDPI, vol. 16(5), pages 1-19, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:14:y:2021:i:4:p:867-:d:495232. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.