Abstract
This paper presents a novel analysis methodology to detect degradation in electrical contacts, with the main goal of implanting a predictive maintenance procedure for sectionalizing switches, circuit breakers, and current transformers in bays of electric transmission and distribution substations. The main feature of the proposed methodology is that it will produce a predictive failure indication for the system under operation, based on the spectral analysis of the load current that is flowing through the bay’s components, using a defined relationship similar to the signal-to-noise ratio (SNR) used in data communication. A highlight of using the proposed methodology is that it is not necessary to make new investments in measurement devices, as the already-existing oscillography measurement infrastructure is enough. By implementing the diagnostic system proposed here, electrical utilities will have a modern tool for monitoring their electrical installations, supporting the implementation of new predictive maintenance functions typical of the current electrical smart grid scenario. Here, we present the preliminary results obtained by the application of the proposed technique using real data acquired from a 230 kV electrical substation, which indicate the effectiveness of the proposed diagnostic procedure.
Suggested Citation
Fábio Vinicius Vieira Bezerra & Gervásio Protásio Santos Cavalcante & Fabrício Jose Brito Barros & Maria Emília Lima Tostes & Ubiratan Holanda Bezerra, 2020.
"Methodology for Predictive Assessment of Failures in Power Station Electric Bays Using the Load Current Frequency Spectrum,"
Energies, MDPI, vol. 13(19), pages 1-14, October.
Handle:
RePEc:gam:jeners:v:13:y:2020:i:19:p:5123-:d:422814
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:19:p:5123-:d:422814. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.