IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v13y2020i17p4351-d402761.html
   My bibliography  Save this article

Online Monitoring of Partial Discharges in Power Transformers Using Capacitive Coupling in the Tap of Condenser Bushings

Author

Listed:
  • Laerty Damião

    (High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
    Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil)

  • João Guimarães

    (Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil
    Energisa, Bragança Paulista SP 12916-360, Brazil)

  • Guilherme Ferraz

    (High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil
    Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil)

  • Edson Bortoni

    (Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil)

  • Ronaldo Rossi

    (Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil)

  • Renato Capelini

    (High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil)

  • Rogério Salustiano

    (High Voltage Equipments—HVEX, Nossa Sra. de Fatima, Itajubá MG 37502-508, Brazil)

  • Estácio Tavares

    (Institute of Electrical Systems and Energy, Federal University of Itajubá, Pinheirinho, Itajubá MG 37500-903, Brazil)

Abstract

Failures in power transformers are one of the most serious occurrences in a power system. Thus, the monitoring of transformers and their ancillary equipment, such as bushings, is of great importance to improving the operational efficiency of these assets. In this context, this paper presents the development of a monitoring system for the measurement of partial discharges (PDs), which are a key parameter in the analysis of insulation condition. PD measurements were performed using the electrical method. For this purpose, a capacitive coupling device was developed for bushings that works as a sensor for high-frequency signals and also as a protection apparatus to guarantee the integrity of the bushings in cases of extreme events, such as lightning surges. In addition, a computational routine is presented that applies a digital filtering process followed by a proposed step for differentiating PDs from noises. For validation, the proposed system was subjected to laboratory tests and field applications, from which the viability of the project and the efficiency in detecting PDs were verified.

Suggested Citation

  • Laerty Damião & João Guimarães & Guilherme Ferraz & Edson Bortoni & Ronaldo Rossi & Renato Capelini & Rogério Salustiano & Estácio Tavares, 2020. "Online Monitoring of Partial Discharges in Power Transformers Using Capacitive Coupling in the Tap of Condenser Bushings," Energies, MDPI, vol. 13(17), pages 1-22, August.
  • Handle: RePEc:gam:jeners:v:13:y:2020:i:17:p:4351-:d:402761
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/13/17/4351/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/13/17/4351/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:13:y:2020:i:17:p:4351-:d:402761. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.